BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z138436
Premises: 3612 BROADWAY MANHATTAN BIN: 1062060     Block: 2080   Lot: 59
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 3612 BROADWAY Census Tract:   233 Health Area:  0620
APT 4C Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10031 Community Board:   109
DOB Cross Street(s):   WEST 148 STREET,    WEST 149 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/22/2013 10:04 AM
Application Entered:   02/22/2013 Job Start Date:   02/22/2013
Last Change:   08/22/2025 Job End Date:   02/22/2014
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   ADAM ADAMSKI       On     05/21/2024      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  
Objection Disposition:  

License #: 010190 Licensee Name: ABE HIMELFARB
Firm: 002663 Firm Name: ALEF ELEC'L CONTR'G INC
Firm Phone: 212-764-2200  Firm Address: 247 WEST 38TH STREET NEW YORK NY 10018 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $70.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: ALL PRO DESIGN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
004  4C  14  30  10  14             
Buildings Total 14  30  10  14                
Total Units : 72 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: 1 - FIRST NOTICE 05/22/2024
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  RISER IS EXISTING FOUR HARD WIRED SMOKE/CARBON DET.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z138436
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/21/2024 05/22/2024 ASK V (40) (3)
INSPECTION COMMENTS: FAIL. INSPECTION COMPLETE. OBJECTION ISSUED. ATOI WILLY

OBJECTION FOR APPLICATION #: Z138436
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (284) NO OUTLET FOR KITCHEN ISLAND
(FLOOR: 004)KITCHEN ISLAND NO OUTLET PROVIDED ART 210.52C2 PROVIDE BEFORE ANDAFTER PHOTO FOR THIS OBJECTION (TUR) NOTE ADDED IN FINALIZATION.
OPEN 05/21/2024 05/21/2024
 
002 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(FLOOR: 004)PANEL DIRECTORY MISSING ART. 408.4 PROVIDE BEFORE AND AFTER PHOTOFOR THIS OBJECTION (TUR) NOTE ADDED IN FINALIZATION.
OPEN 05/21/2024 05/21/2024
 
003 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
(FLOOR: 004)AFCI NOT PROVIDED FOR ALL LISTED AREAS ART 210.12 B PROVIDE BEFOREAND AFTER PHOTO FOR THIS OBJECTION (TUR) NOTE ADDED IN FINALIZATION.
OPEN 05/21/2024 05/21/2024



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order