Electrical Application Details for App #: Z137501
Premises: 845 RIVERSIDE DRIVE MANHATTAN BIN: 1063290     Block: 2135   Lot: 17
   
Application Completed and Certified

Filed: 845 RIVERSIDE DR Census Tract:   247 Health Area:  0500
BASEMENT Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10032 Community Board:   112
DOB Cross Street(s):   EDWARD M MORGAN PLACE,    WEST 160 STREET
Status:   C - JOB IS SIGNED OFF 09/18/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/19/2012 12:18 PM
Application Entered:   11/19/2012 Job Start Date:   11/19/2012
Last Change:   09/18/2014 Job End Date:   01/25/2013
Appointment Status:   
Last Inspection By:   MCPARTLAND, BRIAN       On     09/10/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011198 Licensee Name: BARRY HIRSCH
Firm: 003769 Firm Name: RICO ELECTRIC INC
Firm Phone: 212-564-6284  Firm Address: 450 7TH AVENUE, SUITE 2104 NEW YORK NY 10123 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
E - SUSTAINABLE ENERGY - SOLAR
Total Fee:  $150.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: BERT ESHAGHPOUR
Owner Business Name: GOLD RIVER CAPITAL LLC
Authorized Representative:  BERT ESHAGHPOUR
Relationship To Owner:   SELF


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z137501
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/10/2014 09/18/2014 BMP C (50) (0) Y
INSPECTION COMMENTS: NONE