BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z137488
Premises: 236 WEST 149 STREET MANHATTAN BIN: 1060578     Block: 2034   Lot: 53
   
Application Completed and Certified

Filed: 236 W 149 ST Census Tract:   234 Health Area:  0800
1A-6C104286929 Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10039 Community Board:   110
DOB Cross Street(s):   ADAM CLAYTON POWELL JR BOULEVARD,    FREDERICK DOUGLASS BOULEVARD
Status:   C - JOB IS SIGNED OFF 05/23/2013 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/17/2012 1:15 PM
Application Entered:   11/17/2012 Job Start Date:   11/19/2012
Last Change:   05/23/2013 Job End Date:   01/19/2013
Appointment Status:   
Last Inspection By:   BINGEL, LORI       On     12/20/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011331 Licensee Name: DONALD H RICHARDS
Firm: 002740 Firm Name: GOLDMAN ELECTRIC CORP.
Firm Phone: 347-339-8122  Firm Address: 4460 BAYCHESTER AVENUE BRONX NY 10466 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $224.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: A. ALEAN CONST
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  1A  10             
001  1B  22             
001  1C  10             
002  2A  18             
002  2B  20             
002  2C  16             
003  3A  18             
003  3B  20             
003  3C  16             
004  4A  18             
004  4B  20             
004  4C  16             
005  5A  18             
005  5B  20             
005  5C  16             
006  6A  18             
006  6B  20             
006  6C  16             
Buildings Total 129  312  47  129  129                
Total Units : 746 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 12/08/2012
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALL WIRING IN APARTMENTS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z137488
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/30/2012 12/08/2012 LBI A (35) (3) Y
INSPECTION COMMENTS: N/A
 
(2) 12/20/2012 12/26/2012 LBI C R (30) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: Z137488
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
ENTIRE; APT. PANEL DIRECTORIES ILLEGIBLE AND INACCURATE
RSLV 11/30/2012 11/30/2012 12/20/2012
 
002 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
ENTIRE; SMOKE DECTORS NOT AFCI PROTECTED
RSLV 11/30/2012 11/30/2012 12/20/2012
 
003 (999) OTHER
ENTIRE; AFCI BREAKERS NOT COMBINATION TYPE 210.12(B)
RSLV 11/30/2012 11/30/2012 12/20/2012



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order