BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z137250
Premises: 529 WEST 142 STREET MANHATTAN BIN: 1061850     Block: 2074   Lot: 13
   
Application Completed and Certified

Filed: 529 W 142 ST Census Tract:   229 Health Area:  0620
ENTIRE Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10031 Community Board:   109
DOB Cross Street(s):   HAMILTON PLACE,    BROADWAY
Status:   C - JOB IS SIGNED OFF 07/25/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/22/2012 9:19 AM
Application Entered:   10/22/2012 Job Start Date:   10/23/2012
Last Change:   07/25/2013 Job End Date:   10/12/2013
Appointment Status:   
Last Inspection By:   MCPARTLAND, BRIAN       On     07/08/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011720 Licensee Name: ERIC K AU
Firm: 003306 Firm Name: ERIC & NG ELEC'L, INC.
Firm Phone: 212-673-4118  Firm Address: 155 SUFFOLK STREET NEW YORK NY 10002 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $235.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: GAVTHIER GLEN
Owner Business Name: OWNER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  200AMP
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  #6AWG
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  #3/0AWG
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  24-CIRCUIT
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  1F  11           
002  2F  11               
003  3F  11               
004  4F  11               
Buildings Total 32  44    20  32              
Total Units : 131 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 1 + New Meters 1 - Removed Meters 1 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/22/2012 Notice: 1 - FIRST NOTICE 06/22/2013
Power Issued: 10/22/2012 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z137250
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/07/2013 06/22/2013 JSV A G (30) (5) Y
INSPECTION COMMENTS: VIOL
 
(2) 07/08/2013 07/16/2013 BMP C R E (20) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: Z137250
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 24) ARMORED CABLES ARE NOT PROPERLY SECURED
BSMT/ ARMORED CABLE NOT SUPPORTED PROPERLY
RSLV 06/07/2013 06/07/2013 07/08/2013
 
002 (999) OTHER
ALL/PANELS MULTI BRANCH CKTS NO HANDLE TIE AS PER ART 210.4
RSLV 06/07/2013 06/07/2013 07/08/2013
 
003 (999) OTHER
1FL/WET BAR AREA NO GFI PROTECTION FOR RECEPTACLES WITHIN 6 OF SINKNOT AS PER ART 210.8
RSLV 06/07/2013 06/07/2013 07/08/2013
 
004 (999) OTHER
ALL/CLOSET LIGHTS NOT INSTALL WITH PROPER CLEARNCES NOT AS PER CODEART 410.16
RSLV 06/07/2013 06/07/2013 07/08/2013
 
005 (999) OTHER
BSMT/PANEL,MC CABLE EQUIPMENT GROUPING COND NOT TERMINATED NOT ASPER CODE ART 408.40
RSLV 06/07/2013 06/07/2013 07/08/2013



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order