Electrical Application Details for App #: Z136126
Premises: 2688 BROADWAY MANHATTAN BIN: 1056546     Block: 1874   Lot: 44
   
Application Completed and Certified

Filed: 2688 BROADWAY Census Tract:   191 Health Area:  3110
BASEMENT Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10025 Community Board:   107
DOB Cross Street(s):   WEST 102 STREET,    WEST 103 STREET
Status:   C - JOB IS SIGNED OFF 01/23/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/01/2012 6:10 PM
Application Entered:   08/01/2012 Job Start Date:   08/02/2012
Last Change:   01/23/2013 Job End Date:   08/31/2012
Appointment Status:   
Last Inspection By:   SCHNEIDER, ANDREW       On     01/15/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 012112 Licensee Name: JOSEPH COLOSI
Firm: 003814 Firm Name: LEGACY ELEC'L CONTR'S COR
Firm Phone: 718-357-5305  Firm Address: 150-17B 12TH ROAD WHITESTONE NY 11357 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $135.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   H - Hotel
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: BRANIC INTERNATIONAL RLTY
Authorized Representative:  KEITH ACKER
Relationship To Owner:   MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  1 SET OF #3/0 AWG
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  1 30 CIRCUIT PANEL
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 1 + New Meters 1 - Removed Meters 1 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/01/2012 Notice:  
Power Issued: 08/01/2012 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REPLACEMENT OF DEFECTIVE SERVICE EQUIPMENT: METER PAN AND PANEL.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z136126
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/15/2013 01/23/2013 ARW C E (45) (0) Y
INSPECTION COMMENTS: NONE