BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z125664
Premises: 1921 7 AVENUE MANHATTAN BIN: 1057392     Block: 1901   Lot: 1
   
Application Completed and Certified

Filed: 1921 7TH AV Census Tract:   218 Health Area:  1900
1921 7TH AVENUE Admin Area:   Z - UPPER MANHATTAN Inspection Area:   C
NEW YORK, NY 10026 Community Board:   110
Special Place Name:   ST NICHOLAS AVE
DOB Cross Street(s):   WEST 116 STREET,    WEST 117 STREET
Status:   C - JOB IS SIGNED OFF 11/17/2010
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/22/2010 4:14 PM
Application Entered:   04/22/2010 Job Start Date:   04/22/2010
Last Change:   11/17/2010 Job End Date:   07/22/2010
Appointment Status:   
Last Inspection By:   BANYA, E       On     11/09/2010      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011697 Licensee Name: MICHAEL MURPHY
Firm: 002280 Firm Name: ASSOCIATED ELEC CONT OF N
Firm Phone: 718-882-9520  Firm Address: 27 EAST 233RD STREET NY INC. BRONX NY 10470 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $165.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   REQUIRED
Advisory Board Categories:      K - 1000 KVA SERVICE                            
Advisory Board Approval # / Submittal #:   
Owner / Occup: JOE M MAIO
Owner Business Name: VERIZON WIRELESS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  200 AMP SWITCH
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  SET OF 4/0
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  200AMP 3 PHASE PANEL
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
ROF             
Buildings Total                 
Total Units : 12 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 73 + New Meters 1 - Removed Meters 0 = Total Meters 74

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/22/2010 Notice:  
Power Issued: 04/22/2010 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  200AMP 3PHASE SERVICE SWITCH AND 200AMP PANEL FOR TELECOMMUNICATIONS CABINET

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z125664
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/09/2010 11/17/2010 EBA C E (45) (0) Y
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.