| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
5 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |
| |
| (1) |
05/24/2022 |
05/25/2022 |
GIG |
N |
|
|
(27) |
|
(0) |
Y |
| INSPECTION COMMENTS:
|
SPOKE WITH CONTRACTOR HE SAID THERE WOULD BE NO ACCESS INTO BUILDING INSPECTION INCOMPLETE
|
| |
| (2) |
06/08/2022 |
06/08/2022 |
TOR |
J |
|
|
(30) |
|
(0) |
Y |
| INSPECTION COMMENTS:
|
NO SHOW NO ACCESS CALLED CONTR VISUAL PERFORM FOR APT 2 A NO ACCESS TO OTHER APT
|
| |
| (3) |
08/05/2022 |
08/05/2022 |
SXB |
V |
|
|
(45) |
|
(4) |
|
| INSPECTION COMMENTS:
|
FAIL. INCOMPLETE INSPECTION, INSPECTED 7F AND 4F ONLY.
|
| |
| (4) |
02/14/2024 |
02/15/2024 |
HBU |
J |
R |
|
(40) |
|
(0) |
|
| INSPECTION COMMENTS:
|
FAIL. INCOMPLETE INSPECTION. OBJECTIONS REMOVED. ELECTRICIAN WAS ABESNT. NEED INSPECTION OF APT. 2A,5B AND6D. ATOI RAMOM,BLG. SUPER.
|
| |
| (5) |
02/22/2024 |
02/23/2024 |
DWB |
V |
|
|
(51) |
|
(4) |
|
| INSPECTION COMMENTS:
|
ATOI FRANK-INSPECTION COMPLETE, AS PREVIOUSLY INSPECTED FOR 2 FLR AND 5 FLR. CONTRACTOR TO REFILE APP, NEW OBJECTION ISSUED
|
| |
| (6) |
03/06/2024 |
03/06/2024 |
ASK |
J |
Y |
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
CERTIFIED - OBJ-24-000009443
|
| |
| (7) |
03/06/2024 |
03/06/2024 |
ASK |
J |
Y |
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
CERTIFIED - OBJ-24-000009458
|
| |
| (8) |
03/08/2024 |
03/08/2024 |
EID |
J |
Y |
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
CERTIFIED - OBJ-24-000010241
|
| |
| (9) |
03/25/2024 |
03/25/2024 |
CLC |
C |
R |
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
CERTIFIED - OBJ-24-000012532
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(115) |
GFCI HAS NOT BEEN PROVIDED FOR KITCHEN RECEPTACLES (FLOOR: 004)210.8 GFCI HAS NOT BEEN PROVIDED FOR KITCHEN COUNTER T-OUT |
RSLV |
08/05/2022 |
08/05/2022 |
02/14/2024 |
| |
| 002 |
( 59) |
AFCI PROTECTION HAS NOT BEEN PROVIDED (FLOOR: 004)210.12(B) 2005 NEC AFCI HAS NOT BEEN PROVIDED FOR BEDROOMS |
RSLV |
08/05/2022 |
08/05/2022 |
02/14/2024 |
| |
| 003 |
(283) |
SMALL APPLIANCE OUTLETS NOT PROPERLY LOCATED (FLOOR: 007)210.52(C5) KITCHEN COUNTER MISSING RECEPTACLE LEFT OF SINK |
RSLV |
08/05/2022 |
08/05/2022 |
02/14/2024 |
| |
| 004 |
(211) |
RECEPTACLE IS NOT PROPERLY BONDED/GROUNDED (ALL FLOORS) 250.146 RECEPTACLES ARE NOT GROUNDED TO BOX T-OUT |
RSLV |
08/05/2022 |
08/05/2022 |
02/14/2024 |
| |
| 005 |
(176) |
INSTALLATION DOES NOT MEET CODE REQUIREMENTS (ALL FLOORS)ALL APT-TAMPER RESISTANT OUTLETS MUST BE USED IN RESIDENTIAL 406.11/NOT PROVIDED/INSTALLED. |
RSLV |
02/22/2024 |
02/22/2024 |
03/06/2024 |
| |
| 006 |
(176) |
INSTALLATION DOES NOT MEET CODE REQUIREMENTS (ALL FLOORS)ALL APT-312.4 SURFACES THAT ARE BROKEN OR INCOMPLETE SHALL BEREPAIR,/ENCLOSURE/PANEL INSTALLED W/OPEN GAPS/ GAPS AT PANELS NOTCLOSE. |
RSLV |
02/22/2024 |
02/22/2024 |
03/08/2024 |
| |
| 007 |
(176) |
INSTALLATION DOES NOT MEET CODE REQUIREMENTS (ALL FLOORS)ALL APT-210.52 (C)(1) COUNTER SPACE LONGER THAN 12 INCH REQUIRED ARECEPTACLE/ FROM CONNECTED EDGE AT KITCHEN/ NOT PROVIDED/INSTALLED. |
RSLV |
02/22/2024 |
02/22/2024 |
03/25/2024 |
| |
| 008 |
(999) |
OTHER (ALL FLOORS)CONTRACTOR TO REFILE APPS FOR MISSING EQUIP/PANELS INSTALLED, NOTSHOWN ON OLD APPS Z124892. CONTRACTOR NEED PANELS, 5 OVER 10-2 POLE. |
RSLV |
02/22/2024 |
02/22/2024 |
03/06/2024 |