BIS Menu  |  After Hours Variance Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z123586
Premises: 312 WEST 88 STREET MANHATTAN BIN: 1033979     Block: 1249   Lot: 40
   
Application Completed and Certified

Filed: 312 W 88 ST Census Tract:   175 Health Area:  3120
BASEMENT TO 4TH FL Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10024 Community Board:   107
DOB Cross Street(s):   WEST END AVENUE,    RIVERSIDE DRIVE
Status:   C - JOB IS SIGNED OFF 04/20/2012
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   10/14/2009 Job Start Date:   10/07/2009
Last Change:   04/20/2012 Job End Date:   06/17/2010
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     01/26/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011360 Licensee Name: SERVULUS BILLY
Firm: 003868 Firm Name: POWERONE ELECT'L CONTRG
Firm Phone: 718-241-3236  Firm Address: 1459 BASSETT AVENUE INC BRONX NY 10461 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $663.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: EDMUND SYLVESTER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  5  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  1  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  4  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    16  17                 
BAS    56  25    20    18         
001    36  23    15               
002    33  20    15               
003    35  18    18               
004    32  19    17               
Buildings Total 208  122    94       18           
Total Units : 442 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/14/2009 Notice: 1 - FIRST NOTICE 12/07/2011
Power Issued: 10/14/2009 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z123586
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/18/2011 10/27/2011 GYM P (45) (0) Y
INSPECTION COMMENTS: NO CONTRACTOR ON SITE
 
(2) 11/29/2011 12/07/2011 GYM V E (85) (6) Y
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(3) 01/26/2012 02/03/2012 CLC C R E (45) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: Z123586
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
ALL FL: BEDROOMS
RSLV 11/29/2011 11/29/2011 01/26/2012
 
002 ( 30) OUTLET BOXES ARE NOT SECURED
ROOF: A/C UNITS (6)
RSLV 11/29/2011 11/29/2011 01/26/2012
 
003 (999) OTHER
BSMT: GROUNDING IS NOT OF PROPER SIZE FOR SERVICE ENT.. - TAB.250.66
RSLV 11/29/2011 11/29/2011 01/26/2012
 
004 (999) OTHER
BSMT: ALL AREA MC CABLE NOT BONDED (BASEMENT TO ROOF).... -ART.250.146
RSLV 11/29/2011 11/29/2011 01/26/2012
 
005 ( 53) GFCI HAS NOT BEEN PROVIDED
1ST FL: KITCHEN COUNTER TOP RECEPTS
RSLV 11/29/2011 11/29/2011 01/26/2012
 
006 ( 18) DEFECTIVE RECEPTACLES ARE IN USE
ROOF: G.F.C.I.RECEPTS
RSLV 11/29/2011 11/29/2011 01/26/2012



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  After Hours Variance Permits  |  Electrical Inspection Work Order  |  Back