| BUILDING OVERVIEW |
Are Feeders Being Installed? : Yes |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
2 |
3#2 |
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
2 |
16 CKT |
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
( 14) |
CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE (FLOOR: 002) 12 WIRE 30 AMP BREAKER 240.4 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |
| |
| 002 |
( 19) |
DEFECTIVE WIRING IS IN USE (FLOOR: 002) THREE WIRES UNDER 1 BREAKER 110.3 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |
| |
| 003 |
(211) |
RECEPTACLE IS NOT PROPERLY BONDED/GROUNDED (FLOOR: 002) NO GROUNDS IN OUTLETS T OUT 250.146 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |
| |
| 004 |
( 22) |
FIXED EQUIPMENT IS NOT PROPERLY GROUNDED (FLOOR: 002) MC CABLE NOT TERMINATED IN PANEL 250.8 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |
| |
| 005 |
(229) |
SPLICE BOXES NOT ACCESSIBLE (FLOOR: 002) NO ACCESS TO STOVE OUTLET 314.29 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |
| |
| 006 |
(291) |
BATHROOM RECEPTACLE NOT PROPERLY LOCATED (FLOOR: 002) IMPROPER PLACEMENT GFCI BATHROOM 210.52 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |
| |
| 007 |
( 30) |
OUTLET BOXES ARE NOT SECURED (FLOOR: 002) NO BOX SUPPORT BATHROOM OUTLET 314.1 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |
| |
| 008 |
( 53) |
GFCI HAS NOT BEEN PROVIDED (FLOOR: 002) NO GFCI ON KITCHEN COUNTER 210.8 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |
| |
| 009 |
( 56) |
ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED (FLOOR: 002) BREAKER TYPE DOES NOT MATCH PANEL 110.3 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |
| |
| 010 |
( 59) |
AFCI PROTECTION HAS NOT BEEN PROVIDED (FLOOR: 002) NO AFCI IN BEDROOM 210.12 |
RSLV |
02/28/2023 |
02/28/2023 |
08/11/2023 |