NYC Department of Buildings
Electrical Application Details for App #: Z120579
Premises: 866 RIVERSIDE DRIVE MANHATTAN BIN: 1063310     Block: 2136   Lot: 36
   
Application Completed and Certified

Filed: 870 RIVERSIDE DR Census Tract:   247 Health Area:  0500
3G Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10032 Community Board:   112
DOB Cross Street(s):   EDWARD M MORGAN PLACE,    WEST 160 STREET
Status:   C - JOB IS SIGNED OFF 04/29/2011
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/04/2009 11:05 AM
Application Entered:   02/04/2009 Job Start Date:   02/06/2009
Last Change:   04/29/2011 Job End Date:   02/06/2010
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     01/11/2011      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011749 Licensee Name: JEROME DALY
Firm: 003344 Firm Name: AMRA ELECTRICAL CORP
Firm Phone: 718-444-5209  Firm Address: 1415 UTICA AVENUE BROOKLYN NY 11201 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $87.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOHN KNEILING
Authorized Representative:  JOHN KNEILING
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
003            40             
003  3G  40  30  25               
Buildings Total 40  30  25  40                
Total Units : 141 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 10/20/2010
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z120579
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/05/2010 04/08/2010 CCH A (45) (6) Y
INSPECTION COMMENTS: NONE
 
(2) 10/14/2010 10/20/2010 CLC A R (30) (3) Y
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(3) 01/11/2011 01/18/2011 CLC C R (32) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application

OBJECTION FOR APPLICATION #: Z120579
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
A,BED RM NO ARCH FAULT LIGHTING AND OUTLET
RSLV 04/05/2010 04/05/2010 10/14/2010
 
002 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
B,BED RM, NO ARCH FAULT AC OUTLET
RSLV 04/05/2010 04/05/2010 10/14/2010
 
003 (999) OTHER
PANEL,NEUTRAL BONDED 250.24.A.5
RSLV 04/05/2010 04/05/2010 10/14/2010
 
004 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
PANEL,BREAKER BLANK MISSING
RSLV 04/05/2010 04/05/2010 10/14/2010
 
005 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
PANEL,DIR NOT COMPLETED
RSLV 04/05/2010 04/05/2010 10/14/2010
 
006 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
THRU OUT,HANGING FIXTURES NO GROUNDING WIRE, NOT A FINAL INSPECTION
RSLV 04/05/2010 04/05/2010 10/14/2010
 
007 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
A) BEDROOM NO ARC FAULT LIGHTING AND OUTLET
RSLV 10/14/2010 10/14/2010 01/11/2011
 
008 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
B) BEDROOM NO ARC FAULT AC OUTLET
RSLV 10/14/2010 10/14/2010 01/11/2011
 
009 (999) OTHER
APT.3G: BEDROOMS AC OUTLET LIGHTING NOT A.F.C.I.PROTECTED 210.12B
RSLV 10/14/2010 10/14/2010 01/11/2011



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.