Electrical Application Details for App #: Z101595
Premises: 2525 AMSTERDAM AVENUE MANHATTAN BIN: 1063582     Block: 2149   Lot: 76
   
Application Completed and Certified

Filed: 2525 AMSTERDAM AV Census Tract:   267 Health Area:  0210
4TH & 5TH FLRS Admin Area:   Z - UPPER MANHATTAN Inspection Area:   A
NEW YORK, NY 10033 Community Board:   112
Special Place Name:   MORGENSTERN RESIDENCE HALL
DOB Cross Street(s):   WEST 185 STREET,    WEST 186 STREET
Status:   C - JOB IS SIGNED OFF 11/17/2005
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/12/2004 Job Start Date:   08/09/2004
Last Change:   11/17/2005 Job End Date:   09/01/2004
Appointment Status:   
Last Inspection By:   LAWRENCE HAYES       On     11/10/2005      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 093819 Licensee Name: JEFFREY S SOCOL
Firm: 002941 Firm Name: YESHIVA UNIVERSITY
Firm Phone: 212-960-5362  Firm Address: 500 WEST 185TH ST.-BH303 NEW YORK NY 10033 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $84.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   W - School
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: JEFFREY S SOCOL
Owner Business Name: YESHIVA UNIVERSITY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total   186                      
Total Units : 186 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALLATION OF NEW DUPLEX RECEPTACLES FROM EXISTING BRANCH, CIRCUTING FOR STUDENTS DESK

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z101595
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/10/2005 11/17/2005 LHY C (60) (0) Y
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order