BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z097470
Premises: 220 RIVERSIDE BOULEVARD MANHATTAN BIN: 1086065     Block: 1171   Lot: 7502
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 220 RIVERSIDE BLVD Census Tract:   151 Health Area:  3900
APT# 10N/#10350065901 Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10069 Community Board:   107
DOB Cross Street(s):   WEST 70 STREET,    WEST 71 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   09/10/2003 Job Start Date:   08/27/2003
Last Change:   08/22/2025 Job End Date:   09/30/2003
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   MALLIK HABIBULLAH       On     08/04/2025      
Field Disp:   N - NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 010209 Licensee Name: STEPHEN JACOBY
Firm: 002535 Firm Name: JACOBY ELECTRIC CORP.
Firm Phone: 718-937-9800  Firm Address: 10-40 BORDEN AVENUE LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $51.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: THOMAS PIENKOS
Owner Business Name: THE TRUMP CORPORATION
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 20  10    20                
Total Units : 54 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z097470
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/24/2025 06/25/2025 KVF N (20) (0) Y
INSPECTION COMMENTS: NO ACCESS. ATOI CALLED AND SPOKE WITH CONTRACTOR (STEPHEN JACOBY 929-397-9707) CONTRACTOR STATED THAT HE WOULD RESCHEDULE DUE TO NOT REMEMBERING ABOUT TODAY INSPECTION. WAS UNABLE TO CONDUCT VISUAL INSPECTION DUE TO NOT HAVING ACCESS TO APARTMENT WHERE SCOPE OF WORK WAS DONE. PROCEEDING AS DIRECTED BY OFFICE.
 
(2) 08/04/2025 08/05/2025 HBU N (20) (0) Y
INSPECTION COMMENTS: NO ACCESS. INCOMPLETE INSPECTION. CALLED CONTRACTOR,HE DID NOT RESPOND. OK TO PROCEED AS PER DIRECTED BY OFFICE ASK.




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.