Electrical Application Details for App #: Z089182
Premises: 415 WEST 44 STREET MANHATTAN BIN: 1026411     Block: 1054   Lot: 23
   
Application Completed and Certified

Filed: 415 W 44 ST Census Tract:   121 Health Area:  4500
718 567-2211 NONE Admin Area:   Z - UPPER MANHATTAN Inspection Area:   G
NEW YORK, NY 10036 Community Board:   104
DOB Cross Street(s):    9 AVENUE,    10 AVENUE
Status:   C - JOB IS SIGNED OFF 05/24/2004
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   11/14/2001 Job Start Date:   01/20/2002
Last Change:   05/24/2004 Job End Date:   03/20/2002
Appointment Status:   
Last Inspection By:   PETER GREENE       On     05/10/2004      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011129 Licensee Name: JESUS M CORPORAN
Firm: 002506 Firm Name: JECO ELEC'L SERVICE CORP.
Firm Phone: 718-542-1931  Firm Address: 1162 INTERVALE AVENUE BRONX NY 10459 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $1,378.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: MIKITAR DRAKOTOS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  21  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  21  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                       
Total Units : 4 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 21 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag:
Power Requested: 01/22/2002 Notice: 1 - FIRST NOTICE 11/19/2002
Power Issued: 01/22/2002 Response: F - FILED TO REMOVE OBJECTION 01/22/2002

Follow-Up: X - FILED APPL,NOW CLOSED 01/22/2002
Contractor's Comments:  CROSS ST-9TH AVE 230748

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z089182
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/05/2001 11/14/2001 PGR W (15) (6)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 07/02/2002 07/05/2002 FWE J Y G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 11/14/2002 11/19/2002 PGR V R G (75) (5) Y
INSPECTION COMMENTS: 1)PNL,2)EMT USED OUTSIDE *NOT FINAL PROVIDED ACCESS TO ALL APT
 
(4) 04/21/2004 05/04/2004 LHY P (45) (0) Y
INSPECTION COMMENTS: APPOINTMENT CONT NO SHOW P/U VIOLATION APT #16
 
(5) 05/10/2004 05/24/2004 PGR C R E (60) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back