Electrical Application Details for App #: Z084594
Premises: 2367 8 AVENUE MANHATTAN BIN: 1059380     Block: 1954   Lot: 29
   
Application Completed and Certified

Filed: 2367 8 AV Census Tract:   213.02 Health Area:  8520
BSMT Admin Area:   Z - UPPER MANHATTAN Inspection Area:   C
NEW YORK, NY 10027 Community Board:   110
DOB Cross Street(s):   WEST 127 STREET,    WEST 128 STREET
Status:   C - JOB IS SIGNED OFF 10/19/2001
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   10/03/2000 Job Start Date:   09/04/2000
Last Change:   10/19/2001 Job End Date:   09/26/2000
Appointment Status:   
Last Inspection By:   LAWRENCE HAYES       On     10/12/2001      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011171 Licensee Name: TREVOR DUNWELL
Firm: 002607 Firm Name: APPROVED ELECTRIC CORP.
Firm Phone: 718-882-3145  Firm Address: 3550 WHITE PLAINS ROAD STE #9 BRONX NY 10467 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
8 - BOILER/BURNER WIRING
9 - OTHER
Total Fee:  $34.00
Other Work:   REMOVAL OF VIOLATION
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:  
Owner / Occup: METHA PARAG
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: R - OBJECTION(S) RESOL
Power Requested: Notice:  11/13/2000
Power Issued: Response: F - FILED TO REMOVE OBJECTION 09/06/2001

Follow-Up: X - FILED APPL,NOW CLOSED 09/06/2001
Wires Comments: REMOVE VIOLATION WORK DONE BY OTHERS
Contractor's Comments:  WIRING OF BOILER

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z084594
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/22/2000 10/03/2000 RID W (15) (1)
INSPECTION COMMENTS: NONE
 
(2) 10/12/2001 10/19/2001 LHY C (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application