BIS Menu  |  Pre-BIS PA CO Query By Bin  |  ECB Violations  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z080969
Premises: 2367 8 AVENUE MANHATTAN BIN: 1059380     Block: 1954   Lot: 29
   
Application Completed and Certified

Filed: 2367 8 AV Census Tract:   213.02 Health Area:  8520
077494 BSMT 5F1 4F1 3F1 2 Admin Area:   Z - UPPER MANHATTAN Inspection Area:   C
NEW YORK, NY 10027 Community Board:   110
DOB Cross Street(s):   WEST 127 STREET,    WEST 128 STREET
Status:   C - JOB IS SIGNED OFF 12/07/2000
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/15/1999 Job Start Date:   11/15/1999
Last Change:   10/25/2000 Job End Date:   03/06/2000
Appointment Status:   
Last Inspection By:   DORSAINVILLE, R       On     10/20/2000      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009932 Licensee Name: LOUIS BISANTZ
Firm: 000235 Firm Name: BISANTZ ELEC. CO., INC.
Firm Phone: 718-297-1773  Firm Address: 139-39 JAMAICA AVENUE QUEENS NY 11435 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $1,100.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: PARRG MEHTA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  20  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  20  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 115  460  43  115  115                
Total Units : 848 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 21 #4-Wire 2 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 11/15/1999 Notice:  10/02/2000
Power Issued: 11/15/1999 Response: R - REINSPECTION 10/13/2000

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z080969
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/19/2000 07/24/2000 RID J (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 09/22/2000 10/02/2000 RID V E (90) (3) Y
INSPECTION COMMENTS: A)LIVING RM NO TWO CIRCUIT PROVIDED TO LIVING RM 27-3172B,B)DINING AND NO APPLIANCE CIRC.OUTLETS PROV. AT THE DINNING B.103.044)PNL
 
(3) 10/20/2000 10/25/2000 RID C R E (90) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  ECB Violations  |  Electrical Inspection Work Order  |  Back