BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z078861
Premises: 7 WEST 84 STREET MANHATTAN BIN: 1031342     Block: 1198   Lot: 126
   
Application Completed and Certified

Filed: 7 W 84 ST Census Tract:   169 Health Area:  3500
022743 BOILR RM BULL#8 Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10024 Community Board:   107
DOB Cross Street(s):   CENTRAL PARK WEST,    COLUMBUS AVENUE
Status:   C - JOB IS SIGNED OFF 01/30/2001
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   05/12/1999 Job Start Date:   04/14/1999
Last Change:   01/30/2001 Job End Date:   04/14/1999
Appointment Status:   
Last Inspection By:   PETER GREENE       On     01/25/2001      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 009858 Licensee Name: MARTIN RUBIN
Firm: 000421 Firm Name: DEVORAH ELECTRIC CORP.
Firm Phone: 718-258-0605  Firm Address: 1491 CONEY ISLAND AVE. BROOKLYN NY 11230 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
7 - HVAC WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $22.00
Other Work:   BULLETIN #8
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   A - One Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:  
Owner / Occup: JAMES REISMAN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                       
Total Units : 1 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   OWNER = (HOME)212-595-0586 WORK/212-684-3900 Contact Phone:   212-684-3900(WRK

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag:
Power Requested: 01/17/2001 Notice:  
Power Issued: 01/17/2001 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: CONTACT OWNER FOR ACCESS; WIRED UP BOILER CONTROLS
Contractor's Comments:  1-FAMILY HOME MUST CONTACT OWNER FOR ACCESS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z078861
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/25/2001 01/30/2001 PGR C (75) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application