BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z076730
Premises: 2004 5 AVENUE MANHATTAN BIN: 1053462     Block: 1722   Lot: 35
   
Application Completed and Certified

Filed: 2004 5 AV Census Tract:   200 Health Area:  1500
ENTIRE BLDG Admin Area:   Z - UPPER MANHATTAN Inspection Area:   C
NEW YORK, NY 10035 Community Board:   110
DOB Cross Street(s):   EAST 124 STREET,    EAST 125 STREET
Status:   C - JOB IS SIGNED OFF 09/25/2000
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   10/29/1998 Job Start Date:   10/15/1998
Last Change:   09/25/2000 Job End Date:   02/25/1999
Appointment Status:   
Last Inspection By:   DORSAINVILLE, R       On     09/20/2000      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011464 Licensee Name: THOMAS E JOCELYN III
Firm: 001324 Firm Name: SCIENTIFIC ELEC. CO. INC
Firm Phone: 718-320-2023  Firm Address: 1475 EAST 222ND STREET BRONX NY 10469 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $243.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   X
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: BROWNSTONE PRTNRS/AFF INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  2  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 30  66  19  30                
Total Units : 153 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   CALL FOR ACCESS Contact Phone:   718-861-1203

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/29/1998 Notice:  
Power Issued: 10/29/1998 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: EXISTING VACANT BLDG-NO EXIST.SERV.EQUIP
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z076730
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/16/1999 05/17/1999 RID Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 08/12/1999 08/16/1999 RID J (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 09/20/2000 09/25/2000 RID C E (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back