BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z054532
Premises: 88 CENTRAL PARK WEST MANHATTAN BIN: 1079280     Block: 1121   Lot: 36
  Printable (PDF) version of this Permit  

Filed: 88 CENTRAL PARK W Census Tract:   153 Health Area:  4000
APT 4 SOUTH Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10023 Community Board:   107
DOB Cross Street(s):   WEST 68 STREET,    WEST 69 STREET
Status:   P - OBJECTN PENDING AT CONTRACTOR 05/25/1995
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/04/1993 Job Start Date:   10/29/1993
Last Change:   11/14/1998 Job End Date:   01/30/1994
Appointment Status:   
Last Inspection By:   GLAUBERZON, V       On     05/18/1995      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 007899 Licensee Name: L GODELL
Firm: 002280 Firm Name: ASSOCIATED ELEC CONT OF N
Firm Phone: 718-882-9520  Firm Address: 27 EAST 233RD STREET NY INC. BRONX NY 10470 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $172.25
Other Work:   BASEMENT
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: MRS SACHS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 21  45  21  28     24           
Total Units : 147 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 11/04/1993 Notice: 1 - FIRST NOTICE 05/25/1995
Power Issued: 11/04/1993 Response:  

Follow-Up:
Wires Comments: NEW 100A METER,RISER FROM BASEMENT
Contractor's Comments:  THE BRENTMORE BUILDING

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z054532
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/22/1993 12/28/1993 VG1 J G (40) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 07/29/1994 08/16/1994 VG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 09/01/1994 09/08/1994 VG1 N (5) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 05/18/1995 05/25/1995 VG1 V G (40) (2)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 06/02/1995 06/22/1995 VG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 06/30/1995 07/18/1995 VG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 07/28/1995 08/15/1995 VG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 08/25/1995 09/13/1995 VG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 10/30/1998 11/14/1998 RT1 Z (0) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order