BIS Menu  |  Pre-BIS PA CO Query By Bin  |  After Hours Variance Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z053441
Premises: 247 WEST 139 STREET MANHATTAN BIN: 1060355     Block: 2025   Lot: 11
   
Application Completed and Certified

Filed: 247 W 139 ST Census Tract:   230 Health Area:  1000
BSMT Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10030 Community Board:   110
DOB Cross Street(s):   ADAM CLAYTON POWELL JR BOULEVARD,    PEDESTRIAN PATH
Status:   C - JOB IS SIGNED OFF 12/01/1998
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/13/1993 Job Start Date:   08/09/1993
Last Change:   07/02/1998 Job End Date:   08/23/1993
Appointment Status:   
Last Inspection By:   PRIVATE AGENCY       On     06/12/1998      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 010822 Licensee Name: RICHARD ALLEN
Firm: 002095 Firm Name: ALLEN ELEC CONS ENTP INC.
Firm Phone: 646-224-5984  Firm Address: 3281 BROADWAY NEW YORK NY 10027 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $172.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: MS WANDA HANES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  4  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 11/15/1995 Notice:  04/17/1996
Power Issued: 10/29/1993 Response: W - OBJ TO BE REMOVED 04/22/1996

Follow-Up: K - (CLOSED)
Wires Comments: INSTALL NEW 200AMP ELEC SERVICE
Contractor's Comments:  ADD 1-3W METER AS PER CONTR FAX DTD 10/7/93

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z053441
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/09/1994 05/26/1994 RID A G (0) (1)
INSPECTION COMMENTS: NEUTRAL BAR NOT BONEDE TO ENCLOSURE
 
(2) 11/06/1995 11/15/1995 RID H X B (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 02/28/1996 03/05/1996 IA1 A R G (45) (3)
INSPECTION COMMENTS: N/A
 
(5) 04/09/1996 04/17/1996 IA1 H X G (50) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 05/13/1996 05/20/1996 IA1 N (10) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 01/24/1997 02/10/1997 RID Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 11/14/1997 02/02/1998 X01 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 06/12/1998 07/02/1998 X01 C R G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  After Hours Variance Permits  |  Electrical Inspection Work Order  |  Back