BIS Menu  |  Property Profile  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z051125
Premises: 172 DYCKMAN STREET MANHATTAN BIN: 1064232     Block: 2175   Lot: 66
   
Application Completed and Certified

Filed: 172 DYCKMAN ST Census Tract:   287 Health Area:  0222
031693 STO ONLY Admin Area:   Z - UPPER MANHATTAN Inspection Area:   A
NEW YORK, NY 10040 Community Board:   112
DOB Cross Street(s):   SHERMAN AVENUE,    VERMILYEA AVENUE
Status:   C - JOB IS SIGNED OFF 05/07/1993
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   03/15/1993 Job Start Date:   03/16/1993
Last Change:   04/27/1993 Job End Date:   03/16/1993
Appointment Status:   
Last Inspection By:   THOMAS, T.       On     04/24/1993      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010765 Licensee Name: CESAR QUERY
Firm: 002004 Firm Name: C.Q. ELECTR'L CONTRG CORP
Firm Phone: 718-204-9255  Firm Address: 723 EAST 135TH STREET BRONX NY 10454 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $242.00
Other Work:   SUB FEEDER AND PANEL
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   DRUG STORE
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: GEORGE LAMORENA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 66  12    10  66                
Total Units : 154 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: R - OBJECTION(S) RESOL
Power Requested: Notice:  03/15/1993
Power Issued: Response: F - FILED TO REMOVE OBJECTION 03/19/1993

Follow-Up: X - FILED APPL,NOW CLOSED 03/19/1993
Wires Comments: SERVICE METER WAS ALREADY DONE BY ANOTHER CONTRACTOR LONG AGO
Contractor's Comments:  D B A WORLD DRUGS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z051125
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/05/1993 03/15/1993 RID W (15) (1)
INSPECTION COMMENTS: *THROUGHOUT THE PHAMACY SUBFEEDER SUBPANEL FIXT SW OUTLETS
 
(2) 04/24/1993 04/27/1993 TT1 C E (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Property Profile  |  Electrical Inspection Work Order  |  Back