Electrical Application Details for App #: Z045730
Premises: 435 WEST 45 STREET MANHATTAN BIN: 1026442     Block: 1055   Lot: 15
   
Application Completed and Certified

Filed: 435 W 45 ST Census Tract:   121 Health Area:  4500
BSMT-TOP FL Admin Area:   Z - UPPER MANHATTAN Inspection Area:   G
NEW YORK, NY 10036 Community Board:   104
DOB Cross Street(s):    9 AVENUE,    10 AVENUE
Status:   C - JOB IS SIGNED OFF 09/17/1992
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   03/17/1992 Job Start Date:   02/27/1992
Last Change:   09/08/1992 Job End Date:   05/27/1992
Appointment Status:   
Last Inspection By:   ONA, G.       On     08/25/1992      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 009860 Licensee Name: JOSEPH TODARO
Firm: 001227 Firm Name: REHAB ELECTRICAL CO., INC
Firm Phone: 212-993-6002  Firm Address: 105 BRUCKNER BLVD. BRONX NY 10454 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
2 - TEMPORARY CONSTRUCTION
6 - GENERAL WIRING
Total Fee:  $894.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: 45-435 REALTY CORP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  20  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  18  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  2  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 80  136  34  68  80        18      
Total Units : 422 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 20 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag:
Power Requested: 03/17/1992 Notice:  
Power Issued: 03/17/1992 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  ASSIGN TO GO1 FOR 8/14/92 AS PER FL1 8/27/92

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z045730
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/14/1992 04/21/1992 VG1 I (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 08/25/1992 09/08/1992 GO1 C E (110) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order