Electrical Application Details for App #: Z038113
Premises: 4191 BROADWAY MANHATTAN BIN: 1064271     Block: 2176   Lot: 70
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 4195 BROADWAY Census Tract:   265 Health Area:  0300
1ST FLOOR Admin Area:   Z - UPPER MANHATTAN Inspection Area:   A
NEW YORK, NY 10033 Community Board:   112
DOB Cross Street(s):   WEST 177 STREET,    WEST 178 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   12/10/1990 Job Start Date:   11/30/1990
Last Change:   08/22/2025 Job End Date:   11/30/1990
Appointment Status:   
Last Inspection By:   DORSAINVILLE, R       On     05/20/1991      
Field Disp:   L - LOCATION PROBLEM
Energize Recommendation:  
Objection Disposition:  

License #: 009873 Licensee Name: JOE MIDDLETON
Firm: 001933 Firm Name: NORWAY ELECTRIC CORP.
Firm Phone: 718-992-5500  Firm Address: 1205 JEROME AVENUE BRONX NY 10452 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $41.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   NOT GIVEN
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: PAN AMERICAN INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   10AM TO 3PM Contact Phone:   212/992-5500

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag:
Power Requested: 12/10/1990 Notice:  
Power Issued: 12/10/1990 Response:  

Follow-Up:
Wires Comments: COMPLETE & FILE FOR ELECTRIC WORK STARTED BY OTHER
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z038113
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/20/1991 06/03/1991 RID L (15) (0)
INSPECTION COMMENTS: ASK CONTRACTOR FOR MOR INFORMATION
 
(2) 06/30/1995 02/20/1996 X01 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application