BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z021304
Premises: 326 WEST 76 STREET MANHATTAN BIN: 1031035     Block: 1185   Lot: 38
   

Filed: 326 W 76 ST Census Tract:   163 Health Area:  3400
8820 4770 APT 3 Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10023 Community Board:   107
DOB Cross Street(s):   WEST END AVENUE,    RIVERSIDE DRIVE
Status:   C - SIGNOFF IS AWAITING FEE PAYMENT 12/29/1994
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/11/1988 Job Start Date:   08/09/1988
Last Change:   12/29/1994 Job End Date:   08/15/1988
Appointment Status:   
Last Inspection By:   PRIVATE AGENCY       On     12/08/1994      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 009280 Licensee Name: H WEINSTEIN
Firm: 001532 Firm Name: WILLIAM BEEFERMAN, INC.
Firm Phone: 212-254-3320  Firm Address: 251-28 43RD AVENUE LITTLENECK NY 11363 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $36.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: ANNA ANTONOVSKY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 7 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 10/21/1988 Notice: 1 - FIRST NOTICE 06/14/1990
Power Issued: 10/21/1988 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z021304
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/14/1988 11/01/1988 KJR Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 04/14/1989 05/03/1989 VG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 07/28/1989 08/02/1989 VG1 P (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 05/29/1990 06/14/1990 VG1 A G (40) (1)
INSPECTION COMMENTS: * CAL.LOAD,SV 100A NEW SUBFEEDERS 60A & APTS
 
(5) 12/08/1994 12/29/1994 X01 C G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.