BIS Menu  |  Elev. Device Details  |  DOB Violations  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z016339
Premises: 471 WEST 143 STREET MANHATTAN BIN: 1061272     Block: 2059   Lot: 4
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 471 W 143 ST Census Tract:   227.01 Health Area:  0720
WHOLE HSE Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10031 Community Board:   109
DOB Cross Street(s):   CONVENT AVENUE,    AMSTERDAM AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/22/1988 Job Start Date:   01/18/1988
Last Change:   08/22/2025 Job End Date:   03/18/1988
Appointment Status:   
Last Inspection By:   DORSAINVILLE, R       On     10/03/1997      
Field Disp:   H - NO PROGRESS ON JOB
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  X - NOT REMOVED

License #: 010649 Licensee Name: K KATEN
Firm: 001618 Firm Name: CREATIVE ELECTRON. CO INC
Firm Phone: 212-643-1127  Firm Address: 550 W. 29TH STREET-2ND FL. NEW YORK NY 10001 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $155.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: RON WAGNER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 27  39  17  27                
Total Units : 116 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 03/03/1988 Notice: C - CALL TO OFFICE 10/27/1997
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z016339
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/25/1988 02/26/1988 SKR N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 04/01/1988 04/19/1988 ZB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 08/05/1988 08/23/1988 SKR Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 04/22/1992 04/27/1992 RID A G (30) (2)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 10/03/1997 10/27/1997 RID H X G (30) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Elev. Device Details  |  DOB Violations  |  Electrical Inspection Work Order  |  Back