BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z011181
Premises: 234 WEST 108 STREET MANHATTAN BIN: 1056667     Block: 1879   Lot: 53
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 234 W 108 ST Census Tract:   195 Health Area:  2310
NOT GIVEN Admin Area:   Z - UPPER MANHATTAN Inspection Area:   C
NEW YORK, NY 10025 Community Board:   107
DOB Cross Street(s):   AMSTERDAM AVENUE,    BROADWAY
Status:   E - ABANDONED 08/22/2025
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   06/24/1987 Job Start Date:   11/07/1990
Last Change:   08/22/2025 Job End Date:   11/07/1990
Appointment Status:   
Last Inspection By:   ADMINISTRATION       On     11/05/1999      
Field Disp:   F - POST DISCONNECT WARNING
Energize Recommendation:  
Objection Disposition:  

License #: 010887 Licensee Name: HUGO A PALAVICINO
Firm: 002169 Firm Name: PRESTIGE ELECTRIC CORP.
Firm Phone: 718-584-3784  Firm Address: 341 LAFAYETTE STREET NEW YORK NY 10012 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $5.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   G - Garage
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: JOSEPH BILLING
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 5 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice:  09/19/1990
Power Issued: Response: F - FILED TO REMOVE OBJECTION 11/23/1990

Follow-Up: F - FILED TO REMOVE OBJECTION 11/23/1990
Wires Comments: REPLACE WEATHER ROOF FIXTURES OUT SIDE THIS LOCATION
Contractor's Comments:  ENTRANCE TO BLDG

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z011181
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/15/1987 06/24/1987 AG1 W (0) (2)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 10/05/1987 10/23/1987 KCB F (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 09/19/1990 09/28/1990 RID F (15) (0)
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.