Electrical Application Details for App #: Y183926
Premises: 1038 SOUTHERN BOULEVARD BRONX BIN: 2006018     Block: 2743   Lot: 11
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 1038 SOUTHERN BLVD Census Tract:   119 Health Area:  2900
4, 8, 12, 15, 16 Admin Area:   Y - BRONX Inspection Area:   C
BRONX, NY 10459 Community Board:   202
DOB Cross Street(s):   ALDUS STREET,    WESTCHESTER AVENUE
Status:   C - JOB IS SIGNED OFF 01/24/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/14/2017 3:11 PM
Application Entered:   08/14/2017 Job Start Date:   08/14/2017
Last Change:   01/24/2018 Job End Date:   08/14/2018
Appointment Status:   
Last Inspection By:   GIUSEPPE IMBURGIA       On     01/11/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 012768 Licensee Name: SENAD MEHOVIC
Firm: 004614 Firm Name: E & M ELECTRICAL NY CORP
Firm Phone: 718-281-0158  Firm Address: 193-02 NORTHERN BLVD FLUSHING NY 11358 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $295.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MICHAEL CUNIBERTI
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  5  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  5  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002  18  35  10  18         
003  18  35  10  18         
004  12  18  35  10  18         
005  15  18  35  10  18         
005  16  18  35  10  18         
Buildings Total 90  175  20  50  90              
Total Units : 430 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 5 #4-Wire 0 #10-Wire 0
Existing Meters 21 + New Meters 5 - Removed Meters 5 = Total Meters 21

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/14/2017 Notice:  
Power Issued: 08/14/2017 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y183926
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/11/2018 01/11/2018 GIG C (45) (0) Y
INSPECTION COMMENTS: WORK TO 5 APARTMENTS DO TO FIRE DAMAGE INSPECTION PASSED