BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y182979
Premises: 925 HUNTS POINT AVENUE BRONX BIN: 2129345     Block: 2735   Lot: 20
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 925 HUNTS POINT AV Census Tract:   89
1 Admin Area:   Y - BRONX Inspection Area:   C
BRONX, NY 10459 Community Board:   202
Special Place Name:   MCDONALD'S
DOB Cross Street(s):   BRUCKNER BOULEVARD,    EAST 163 STREET
Status:   C - JOB IS SIGNED OFF 02/01/2018
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   06/20/2017 Job Start Date:   06/21/2017
Last Change:   02/01/2018 Job End Date:   05/11/2018
Appointment Status:   
Last Inspection By:   GIUSEPPE IMBURGIA       On     02/01/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009615 Licensee Name: ROBERT COVELLO
Firm: 001205 Firm Name: ROBERT S. COVELLO
Firm Phone: 718-786-7390  Firm Address: 51-20 35TH STREET L.I.C. NY 11101 

Work Started or Filed by Others: NO
Work Category:   U - UN-TAGGED SIGN Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $130.00
Other Work:   SIGN WORK
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   K - Store
Store / Other:   RESTAURANT
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: BRUCE COLLEY
Owner Business Name: MCDONALD'S
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 1 Tags:

Sign Dimensions : 2 Ft 0 In  BY  15 Ft 11 In  Total Sq. Ft. of Sign: 32
Sign Type : A
Total Circuits: 1 Total Lamps: 0
Watts (Lamps): 0 Number of Trans: 1 VA of Each Trans: 120
Total Watts or VA: 120 A.W. Gauge of Wire: 12 No. of Sockets Per Circuit: 0
Material/Gauge: 3/16"ACRYLIC, .067 ALUM
Sign Maker : DCI SIGNS
Sign Maker Address: 110 RIVERSIDE AVENUE, NEWARK, NJ 07104
Shop Address:
Shop Phone:
Shop Location Comments:
Sign Text: M MCDONALD'S

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 09/19/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  CONNECTION AND TAG FOR CHANNEL LETTERS (M MCDONALD'S)

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y182979
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/18/2017 09/19/2017 JRP V (30) (1)
INSPECTION COMMENTS: FAIL
 
(2) 02/01/2018 02/01/2018 GIG C R (20) (0)
INSPECTION COMMENTS: INSPECTION PASSED

OBJECTION FOR APPLICATION #: Y182979
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(GROUND FLOOR) SIGN CIRCUIT NOT LABEL IN PANEL 408.4
RSLV 09/18/2017 09/18/2017 02/01/2018



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order