| NYC Department of Buildings | ||
| Electrical Application Details for App #: Y178909 | ||
| Premises: 5900 ARLINGTON AVENUE BRONX | BIN: 2086321 Block: 5953 Lot: 240 |
| Printable (PDF) version of this Permit | |||||||||||
| DOB NOW: Inspections | |||||||||||
| Filed: | 5900 ARLINGTON AV | Census Tract: 323 | ||
| CELLAR | Admin Area: Y - BRONX | Inspection Area: H | ||
| BRONX, NY 10471 | Community Board: 208 | |||
| Special Place Name: BUILDING 3 | ||||
| DOB Cross Street(s): WEST 259 STREET, INDEPENDENCE AVENUE | |||
| Status: E - ABANDONED 08/22/2025 | |||
| Request Type: A - APPLICATION | eFiled: NO | ||
| Application Entered: 08/15/2016 | Job Start Date: 08/05/2016 | ||
| Last Change: 08/22/2025 | Job End Date: 12/15/2016 | ||
| COMPLETION FEE WAS BILLED | |||
| Appointment Status: | |||
| Last Inspection By: On | |||
| Field Disp: | |||
| Energize Recommendation: | |||
| Objection Disposition: | |||
| License #: | 011355 | Licensee Name: | CARMINE L LIPPOLIS | |
| Firm: | 002775 | Firm Name: | LIPPOLIS ELECTRIC, INC. | |
| Firm Phone: | 718-892-4055 | Firm Address: | 4459 BRONX BOULEVARD BRONX NY 10470 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: R - REHABILITATION | Work To Be Done:
6 - GENERAL WIRING |
Total Fee: $698.75 | ||||||
| Hurricane Sandy Damage: No | ||||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: L - Five Or More Family | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: REQUIRED | |||||||
| Advisory Board Categories: K - 1000 KVA SERVICE | |||||||
| Advisory Board Approval #: 51877 Submittal #: 12A0220CO | |||||||
| Owner / Occup: | |||||||
| Owner Business Name: | SKYVIEW OWNERS CORP | ||||||
| Authorized Representative: SEAN PRINGLE | |||||||
| Relationship To Owner: GC-PROJECT MANAGER | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| CEL | 1 | 8 | 2 | 155 | ||||||||
| CEL | 2 | 16 | 89 | |||||||||
| Buildings Total | 1 | 8 | 244 | |||||||||
| Total Units : 253 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 0 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 0 | + New Meters | 0 | - Removed Meters | 0 | = Total Meters | 0 |
| Power Auth Flag: | Objection Flag: | ||
| Power Requested: | Notice: | ||
| Power Issued: | Response: |
| Follow-Up: | |||
| Contractor's Comments: WIRING FOR CO-GEN SYSTEM INSTALLATION. ITEMS INSTALLED BUT LEFT OFF OF PERMIT Y154547. REMOVE ECB#35158949Y&35158950K | |||
|
|
| *NO INSPECTION RECORDS FOUND FOR ELECTRICAL APPLICATION NUMBER Y178909 |
| INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |