BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y178003
Premises: 285 EAST 138 STREET BRONX BIN: 2000689     Block: 2314   Lot: 10
   

DOB NOW: Inspections


Filed: 285 E 138TH ST Census Tract:   39 Health Area:  4500
BASEMENT, 1 - 11 FLOORS Admin Area:   Y - BRONX Inspection Area:   A
BRONX, NY 10454 Community Board:   201
Related Job Number:    220462407
DOB Cross Street(s):   LINCOLN AVENUE,    ALEXANDER AVENUE
Status:   K - CLOSED/CANCELLED 03/07/2019
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/07/2016 6:52 PM
Application Entered:   06/07/2016 Job Start Date:   06/07/2016
Last Change:   03/07/2019 Job End Date:   07/17/2017
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     03/06/2019      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 011252 Licensee Name: ALBERT DATTOLO
Firm: 001211 Firm Name: RAINBOW ELECTRIC CO., INC
Firm Phone: 718-521-0926  Firm Address: 76-18 ROCKAWAY BLVD WOODHAVEN NY 11421 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
T - TEMPORARY LIGHT & POWER
Total Fee:  $1,137.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JENNIFER STEINBERG
Owner Business Name: WEST SIDE FEDERATION FOR
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  2  400 AMP SWITCH
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  3/0
D. Over 250 MCM  2  2 SETS OF 500
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  200
D. 3 Phase Over 225 AMPS  2  2 400
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    150             
001    150             
002    150             
003    150             
004    150             
005    150             
006    150             
007    150             
008    150             
009    150             
010  10    150             
011  11    150             
Buildings Total 60  60    60  1800                
Total Units : 1980 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 1 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/07/2016 Notice:  
Power Issued: 06/07/2016 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  TEMPORARY LIGHT AND POWER

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y178003
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/13/2018 09/14/2018 GYM G (30) (0) Y
INSPECTION COMMENTS: TEMP. LIGHTS IN COMMERCIAL SPACE. APP NEED TO CERTIFIED.
 
(2) 02/23/2019 02/25/2019 GYM J (45) (0) Y
INSPECTION COMMENTS: TEMP.
 
(3) 03/06/2019 03/07/2019 CLC K (3) (0) Y
INSPECTION COMMENTS: OK TO CANCEL REFER TO APP# X00134816




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back