BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y177396
Premises: 2041 GRAND AVENUE BRONX BIN: 2114829     Block: 3206   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 57 W BURNSIDE AV Census Tract:   251 Health Area:  1520
57 WEST BURNSIDE AVE Admin Area:   Y - BRONX Inspection Area:   F
BRONX, NY 10453 Community Board:   205
Special Place Name:   MID BRONX ENDOSCOPY
Related Job Number:    220522487
DOB Cross Street(s):   GRAND AVENUE,    HARRISON AVENUE
Status:   C - JOB IS SIGNED OFF 06/13/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/26/2016 12:16 PM
Application Entered:   04/26/2016 Job Start Date:   04/26/2016
Last Change:   06/13/2017 Job End Date:   04/26/2016
Appointment Status:   
Last Inspection By:   JOFFRE PENA       On     06/12/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 012349 Licensee Name: ANTHONY SOFIA
Firm: 004134 Firm Name: BIG ANT ELECTRIC, INC
Firm Phone: 646-825-3008  Firm Address: 405 LEXINGTON AVENUE, 26TH FL **CHRYSLER BUILDING*** NEW YORK NY 10174 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
7 - HVAC WIRING
L - LIGHTING WORK
Total Fee:  $515.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  220522487
Building Used As:   I - Hospital Or Health Facility
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOHN GLIELMI
Owner Business Name: MID BRONX ENDOSCOPYCTRLLC
Authorized Representative:  JOHN GLIELMI
Relationship To Owner:   GC


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  4  4 AC UNITS 30 AMP 3 PHASE
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  400 AMP SAFETY SWITCH
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  4  30AMP 3PHASE #10 AWG WIRE
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  1SET OF 4-250MCM COPPERWI
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  225 AMPS
D. 3 Phase Over 225 AMPS  1  3PHASE 208/120V 250AMCB
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
003    176  207                60 
Buildings Total 176  207                     60 
Total Units : 443 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  BUILD OUT OF NEW ENDOSCOPY OFFICE.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y177396
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/12/2017 06/13/2017 JRP C (60) (0) Y
INSPECTION COMMENTS: PASS