| BUILDING OVERVIEW |
Are Feeders Being Installed? : Yes |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
1 |
100A |
| B. 101 Up to 200 AMPS |
1 |
200A |
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
6 |
2-1200A, 4-800A |
| E. Over 1200 AMPS |
2 |
2500A |
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
40 |
3#2/0 |
| B. Over #2 to 1/0 |
100 |
3#1/0 |
| C. Over 1/0 to 250 MCM |
2 |
4#3/0 |
| D. Over 250 MCM |
12 |
4#500MCM |
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
140 |
4 WIRE |
| C. 3 Phase Up to 225 AMPS |
10 |
200A 3P |
| D. 3 Phase Over 225 AMPS |
2 |
600A 3P, 1200A 3P |
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(999) |
OTHER (ALL FLOORS) ALL GFCI OUTSIDE 2ND FLOOR AND ROOF NOT WR 406.8(B) |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |
| |
| 002 |
(999) |
OTHER (ALL FLOORS)ALL HEATERS IN BATHROOMS NOT LISTED FOR DAMP LOCATIONS 242.12(B)110.3 |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |
| |
| 003 |
(999) |
OTHER (ALL FLOORS) ALL HEATERS IN BATHROOMS OVER FUSE 240.3 |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |
| |
| 004 |
(999) |
OTHER (ALL FLOORS) ALL DIRECTORIES IN THE APARTMENTS ARE MISLABEL 408.4 |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |
| |
| 005 |
(999) |
OTHER (BASEMENT) TEMP POWER NOT REMOVED 590.3 |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |
| |
| 006 |
(999) |
OTHER (BASEMENT) OVER CURRENT PROTECTION OVER FUSE IN LAUNDRY ROOM 240.3 |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |
| |
| 007 |
(999) |
OTHER (BASEMENT) NEEDS FIRE STOP BY GARAGE DOOR 300.21 |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |
| |
| 008 |
(999) |
OTHER (BASEMENT)NO GFCI RECEPTACLES IN LAUNDRY ROOM WITHIN 6 FEET OF WATER210.8(B)(5) |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |
| |
| 009 |
(999) |
OTHER (GROUND FLOOR)LFMC MORE THAN 6 FEET BY GARAGE DOOR AMENDMENT 350.12(3) |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |
| |
| 010 |
(999) |
OTHER (ROOF) DISCONNECT FOR MOTOR NOT ON SIGHT ON ROOF ABOVE STAIRS 430.102(B) |
RSLV |
04/26/2017 |
04/26/2017 |
08/03/2017 |