BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y167085
Premises: 2011 VALENTINE AVENUE BRONX BIN: 2127651     Block: 3149   Lot: 65
   
Application Completed and Certified

Filed: 2017 VALENTINE AV Census Tract:   381 Health Area:  1700
BASEMENT TO 7TH FLOOR Admin Area:   Y - BRONX Inspection Area:   I
BRONX, NY 10457 Community Board:   205
Related Job Number:    220245811
DOB Cross Street(s):   EAST BURNSIDE AVENUE,    EAST 180 STREET
Status:   C - JOB IS SIGNED OFF 01/09/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/13/2014 10:40 AM
Application Entered:   01/13/2014 Job Start Date:   01/13/2014
Last Change:   01/09/2015 Job End Date:   01/13/2016
Appointment Status:   
Last Inspection By:   SCHIAVO, JAMES       On     11/28/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 012361 Licensee Name: ANGELO DOMINGUEZ
Firm: 004263 Firm Name: ALLTECH ELECL CONTNG CORP
Firm Phone: 646-491-2088  Firm Address: 227 SEA BREEZE AVE., STE 201 BROOKLYN NY 11224 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $2,423.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ARJAN GJUSHI
Owner Business Name: GJUSHI CONSTRUCTION CO.
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  3  400A
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  6  SETS 500 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  38  60A, 12/24
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  200A
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  1  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  38  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS  00  20  10    15               
001  1A  25               
001  1B  25               
002  2A  25               
002  2B  25               
002  2C  25               
002  2D  25               
002  2E  25               
002  2F  25               
003  3A  25               
003  3B  25               
003  3C  25               
003  3D  25               
003  3E  25               
003  3F  25               
004  4A  25               
004  4B  25               
004  4C  25               
004  4D  25               
004  4E  25               
004  4F  25               
005  5A  25               
005  5B  25               
005  5C  25               
005  5D  25               
005  5E  25               
005  5F  25               
006  6A  25               
006  6B  25               
006  6C  25               
006  6D  25               
006  6E  25               
006  6F  25               
007  7A  25               
007  7B  25               
007  7C  25               
007  7D  25               
007  7E  25               
007  7F  25               
Buildings Total 324  960  76  319                  
Total Units : 1679 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 38 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 01/13/2014 Notice:  
Power Issued: 01/13/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  GENERAL WIRING AND SERVICE WORK

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y167085
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/28/2014 12/05/2014 JSV C E (30) (0) Y
INSPECTION COMMENTS: C




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order