Electrical Application Details for App #: Y166713
Premises: 1564 TAYLOR AVENUE BRONX BIN: 2028706     Block: 3925   Lot: 25
   
Application Completed and Certified

Filed: 1564 TAYLOR AV Census Tract:   216.01 Health Area:  1310
APT 6G Admin Area:   Y - BRONX Inspection Area:   J
BRONX, NY 10460 Community Board:   209
Special Place Name:   APT 6G & BSMT 200 AMP
DOB Cross Street(s):   GUERLAIN STREET,    EAST TREMONT AVENUE
Status:   C - JOB IS SIGNED OFF 03/21/2014
Request Type:   P - PICK-UP eFiled:   YES
Application Entered:   01/26/2014 Job Start Date:   01/27/2014
Last Change:   03/21/2014 Job End Date:   03/31/2014
Appointment Status:    Complaint Number:    2192382
Last Inspection By:   DIMAGGIO, PHILLIP       On     03/11/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011015 Licensee Name: ERROL G GLANVILLE
Firm: 002353 Firm Name: THROOP ELECTRIC CO., INC.
Firm Phone: 718-282-8201  Firm Address: 610 ROGERS AVENUE BROOKLYN NY 11225 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $40.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: HOWARD MILLER
Owner Business Name: 1564 TAYLOR LLC C/O MILLE
Authorized Representative:  HOWARD MILLER
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
006  6G                     
Buildings Total                       
Total Units : 3 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  11/26/2013
Power Issued: Response: F - FILED TO REMOVE OBJECTION 01/26/2014

Follow-Up: X - FILED APPL,NOW CLOSED 01/26/2014
Contractor's Comments:  NO GFCI PROVIDED & BONDED SERVICE SWITCH. FILING THE CORRECTION FIOR THE ECB#35037785X AND ECB 35037786H.FOR GROUND RODFOR 2-400AMP SWITCH AND RECONNET WATER PIPE FROUND

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y166713
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/25/2013 11/26/2013 RID W (15) (5)
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 03/11/2014 03/17/2014 PDI C R (60) (0) Y
INSPECTION COMMENTS: CERT

OBJECTION FOR APPLICATION #: Y166713
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
APT 6G KITCHEN OUTLETS. 210.8COM: THE NEW RECEPTACLE OUTLETS ARE NOT GFCI
RSLV 11/25/2013 11/25/2013 03/11/2014
 
002 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
BSMT SERVICE EQUIPMENT 200 AMPCOM: NEUTRAL BAR NOT BONDED TO ENCLOSURE
RSLV 11/25/2013 11/25/2013 03/11/2014
 
003 (999) OTHER
BSMT 200 AMP SERVICE SWITCHCOM: THE MIC ARE MISSING SERV, ENTRANCE CONDUCTOR
RSLV 11/25/2013 11/25/2013 03/11/2014
 
004 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
SUB PANEL APT 6GCOM: NO DIRECTORY PROVIDED
RSLV 11/25/2013 11/25/2013 03/11/2014
 
005 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
THIS IS NOT A FINAL INSPECTION. SEE THIS COMPLAINT #2192382
RSLV 11/25/2013 11/25/2013 03/11/2014