BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y163337
Premises: 3961 CARPENTER AVENUE BRONX BIN: 2062845     Block: 4820   Lot: 20
   
Application Completed and Certified

Filed: 3961 CARPENTER AV Census Tract:   408 Health Area:  0610
STREET Admin Area:   Y - BRONX Inspection Area:   L
BRONX, NY 10466 Community Board:   212
Related Job Number:    220119459
DOB Cross Street(s):   EAST 224 STREET,    EAST 225 STREET
Status:   C - JOB IS SIGNED OFF 08/22/2013 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/13/2013 3:11 AM
Application Entered:   03/13/2013 Job Start Date:   03/14/2013
Last Change:   08/22/2013 Job End Date:   03/14/2014
Appointment Status:   
Last Inspection By:   SCHIAVO, JAMES       On     06/18/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 012361 Licensee Name: ANGELO DOMINGUEZ
Firm: 004263 Firm Name: ALLTECH ELECL CONTNG CORP
Firm Phone: 646-491-2088  Firm Address: 227 SEA BREEZE AVE., STE 201 BROOKLYN NY 11224 

Work Started or Filed by Others: YES
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $1,282.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MARK STAGG
Owner Business Name: B.E. BRONX BUILDERS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  3 PHASE 100 AMP
B. 101 Up to 200 AMPS  1  3 PHASE 200 AMP
C. 201 Up to 600 AMPS  2  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  2  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  4  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  1A  25               
001  1B  25               
001  1C  25               
001  1E  25               
001  1F  25               
001  1G  25               
001  1H  25               
002  2A  25               
002  2B  25               
002  2C  25               
002  2D  25               
002  2E  25               
002  2F  25               
002  2G  25               
002  2H  25               
002  2J  25               
002  2K  25               
003  3A  25               
003  3B  25               
003  3C  25               
003  3D  25               
003  3E  25               
003  3F  25               
003  3G  25               
003  3H  25               
003  3J  25               
003  3K  25               
004  4A  25               
004  4B  25               
004  4C  25               
004  4D  25               
004  4E  25               
004  4F  25               
004  4G  25               
004  4H  25               
004  4J  25               
004  4K  25               
005  5A  25               
005  5B  25               
005  5C  25               
005  5D  25               
005  5E  25               
005  5F  25               
005  5G  25               
005  5H  25               
005  5J  25               
005  5K  25               
006  6A  25               
006  6B  25               
006  6C  25               
006  6D  25               
006  6E  25               
006  6F  25               
006  6G  25               
006  6H  25               
006  6J  25               
006  6K  25               
Buildings Total 456  1425  114  342                  
Total Units : 2337 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 58 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/13/2013 Notice: 1 - FIRST NOTICE 06/06/2013
Power Issued: 03/13/2013 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y163337
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/23/2013 06/06/2013 JSV A G (60) (4) Y
INSPECTION COMMENTS: VIOL
 
(2) 06/18/2013 06/22/2013 JSV C R E (20) (0) Y
INSPECTION COMMENTS: ISSUE FINAL CERTIFICATE

OBJECTION FOR APPLICATION #: Y163337
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
BSMT/ PLP PANELS (3) NOT PROVIDED WITH DIRECTORY
RSLV 05/23/2013 05/23/2013 06/18/2013
 
002 (999) OTHER
BSMT/SERVICE ROOM (2)400A SWITCHES,300 MCM CONDUCTORS OVERFUSED AT350A NOT AS PER CODE ART 310.16
RSLV 05/23/2013 05/23/2013 06/18/2013
 
003 (999) OTHER
BSMT/SERVICE FOR ELEVATOR NOT PROVIDED WITH NEUTRAL CONDUCTORS ASPER ART 250.24(C)
RSLV 05/23/2013 05/23/2013 06/18/2013
 
004 (999) OTHER
BSMT/SERVICE RM,PLP; MULITWIRE BRANCH CKTS NO HANDLE TIE AS PER ART210.4
RSLV 05/23/2013 05/23/2013 06/18/2013



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order