Electrical Application Details for App #: Y161869
Premises: 3401 BAINBRIDGE AVENUE BRONX BIN: 2096399     Block: 3327   Lot: 1
   
Application Completed and Certified

Filed: 111 E 210 ST Census Tract:   421 Health Area:  0410
THIRD FLOOR Admin Area:   Y - BRONX Inspection Area:   H
BRONX, NY 10467 Community Board:   207
DOB Cross Street(s):   STEUBEN AVENUE,    ROCHAMBEAU AVENUE
Status:   C - JOB IS SIGNED OFF 05/15/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/15/2012 9:58 AM
Application Entered:   10/15/2012 Job Start Date:   10/16/2012
Last Change:   05/15/2013 Job End Date:   01/30/2013
Appointment Status:   
Last Inspection By:   SCHIAVO, JAMES       On     05/06/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 012236 Licensee Name: NIKOLL DUSHI
Firm: 003974 Firm Name: NEW AGE ELEC'L CONTRG INC
Firm Phone: 718-738-4488  Firm Address: 86-16 101ST AVENUE OZONE PARK NY 11416 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $296.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   I - Hospital Or Health Facility
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: MONTEFIORE MEDICAL CENTER
Authorized Representative:  RONALD HELLMAN
Relationship To Owner:   GENERAL CONTRACTOR


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  (2)#4 AWG, (1) #8 G
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  (4) 350 AWG, (1) #4 G
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  2  DUAL SYSTEM ISOLATION
C. 3 Phase Up to 225 AMPS  1  42 CIRCUIT 277/480 VOLT
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
003    30  52    30             
Buildings Total 30  52    30                
Total Units : 117 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  DAVINCI OR 19 REWIRE FOR LIGHT AND POWER

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y161869
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/06/2013 05/15/2013 JSV C (45) (0) Y
INSPECTION COMMENTS: CERT