| NYC Department of Buildings | ||
| Electrical Application Details for App #: Y158823 | ||
| Premises: 499 EAST 188 STREET BRONX | BIN: 2127594 Block: 3058 Lot: 41 |
| DOB NOW: Inspections | |||||||||||
| Application Completed and Certified | |||||||||||
| Filed: | 499 E 188 ST | Census Tract: 387 | Health Area: 1000 | |
| ENTIRE BLDG | Admin Area: Y - BRONX | Inspection Area: I | ||
| BRONX, NY 10458 | Community Board: 206 | |||
| Related Job Number: 201066489 | |||
| DOB Cross Street(s): WASHINGTON AVENUE, BATHGATE AVENUE | |||
| Status: C - JOB IS SIGNED OFF 01/10/2017 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 01/27/2012 2:16 PM | |
| Application Entered: 01/27/2012 | Job Start Date: 01/27/2012 | ||
| Last Change: 01/10/2017 | Job End Date: 01/26/2013 | ||
| Appointment Status: | |||
| Last Inspection By: DIMAGGIO, PHILLIP On 12/30/2016 | |||
| Field Disp: C - INSPECTION PASSED | |||
| Energize Recommendation: E - ISSUE POWER AUTH | |||
| Objection Disposition: R - REMOVED | |||
| License #: | 011041 | Licensee Name: | SALVATORE CHIARAMONTE | |
| Firm: | 003893 | Firm Name: | L&B ELEC'L INTERNATIONAL | |
| Firm Phone: | 347-295-0380 | Firm Address: | 150-50 11TH AVENUE WHITESTONE NY 11357 | |
| Work Started or Filed by Others: NO | ||||||||
| Work Category: N - NEW BUILDING | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY 6 - GENERAL WIRING 7 - HVAC WIRING |
Total Fee: $1,544.25 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: YES | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: No | ||||||||
| Building Used As: L - Five Or More Family | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | BRONX NY E 188 ST APARTMENTS LP | ||||||
| Owner Business Name: | BRONX NY E 188 ST APTS LP | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| CEL | 45 | 5 | 5 | 10 | 5 | 49 | 10 | 1 | ||||
| 001 | 28 | 5 | 5 | 10 | 10 | 1 | ||||||
| 002 | 35 | 85 | 10 | 10 | 10 | 1 | 1 | |||||
| 003 | 35 | 85 | 10 | 10 | 10 | 1 | 1 | |||||
| 004 | 35 | 85 | 10 | 10 | 10 | 1 | 1 | |||||
| 005 | 35 | 85 | 10 | 10 | 10 | 1 | 1 | |||||
| 006 | 35 | 85 | 10 | 10 | 10 | 1 | 1 | |||||
| 007 | 35 | 85 | 10 | 10 | 10 | 1 | 1 | |||||
| 008 | 35 | 85 | 10 | 10 | 10 | 1 | 1 | |||||
| 009 | 41 | 85 | 10 | 10 | 10 | 1 | 1 | |||||
| ROF | BULKH | 1 | 1 | 1 | 1 | 5 | 41 | |||||
| ROF | LOWER | 3 | 2 | |||||||||
| ROF | ROOF | 5 | 5 | 3 | 3 | 8 | 6 | |||||
| Buildings Total | 365 | 696 | 80 | 94 | 104 | 106 | 2 | |||||
| Total Units : 1447 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 41 | #4-Wire | 0 | #10-Wire | 0 | |
| Existing Meters | 0 | + New Meters | 0 | - Removed Meters | 0 | = Total Meters | 0 |
| Power Auth Flag: | I - ISSUED | Objection Flag: | |
| Power Requested: | 01/27/2012 | Notice: | 1 - FIRST NOTICE 11/30/2016 |
| Power Issued: | 01/27/2012 | Response: |
| Follow-Up: | K - (CLOSED) | ||
| Contractor's Comments: | |||
|
|