Electrical Application Details for App #: Y155890
Premises: 2842 GRAND CONCOURSE BRONX BIN: 2017145     Block: 3304   Lot: 119
   
Application Completed and Certified

Filed: 2842 GRAND CONCOURSE Census Tract:   403.02 Health Area:  0900
APT. 3J Admin Area:   Y - BRONX Inspection Area:   F
BRONX, NY 10458 Community Board:   207
DOB Cross Street(s):   EAST 197 STREET,    EAST 198 STREET
Status:   C - JOB IS SIGNED OFF 12/01/2011
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/23/2011 10:32 AM
Application Entered:   05/23/2011 Job Start Date:   05/23/2011
Last Change:   12/01/2011 Job End Date:   08/23/2011
Appointment Status:   
Last Inspection By:   ASHMAN, K.       On     11/02/2011      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 010765 Licensee Name: CESAR QUERY
Firm: 002004 Firm Name: C.Q. ELECTR'L CONTRG CORP
Firm Phone: 718-204-9255  Firm Address: 723 EAST 135TH STREET BRONX NY 10454 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $65.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: VED PARKASH
Owner Business Name: PARKASH 2842, LLC
Authorized Representative:  EUGENIO SANCHEZ
Relationship To Owner:   CONSTRUCTION MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  100 AMP. 1 PHASE 16 CIRC.
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
003  3J  10  20  10             
Buildings Total 10  20  10                
Total Units : 50 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  DOB-2K11-034 APT. 3J FIRE DAMAGED

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y155890
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/29/2011 09/12/2011 GYM N (25) (0) Y
INSPECTION COMMENTS: NO ACCESS
 
(2) 11/02/2011 11/18/2011 KAS C G (45) (0) Y
INSPECTION COMMENTS: CERT