Electrical Application Details for App #: Y153739
Premises: 950 WESTCHESTER AVENUE BRONX BIN: 2114693     Block: 2703   Lot: 7501
   
Application Completed and Certified

Filed: 975 KELLY ST Census Tract:   87 Health Area:  3700
BSMT/1FL/SUPERMARKET Admin Area:   Y - BRONX Inspection Area:   C
BRONX, NY 10459 Community Board:   202
DOB Cross Street(s):   EAST 163 STREET,    WESTCHESTER AVENUE
Status:   C - JOB IS SIGNED OFF 08/07/2014
Request Type:   P - PICK-UP eFiled:   YES
Application Entered:   11/07/2013 Job Start Date:   11/11/2013
Last Change:   08/07/2014 Job End Date:   11/27/2013
Appointment Status:   
Last Inspection By:   DIMAGGIO, PHILLIP       On     04/09/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012332 Licensee Name: ROBERT D WEDDERBURN
Firm: 004114 Firm Name: JANON ELECTRIC CORP
Firm Phone: 718-898-1500  Firm Address: 35-58 9TH STREET LONG ISLAND CITY NY 11106 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $340.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   K - Store
Store / Other:   RETAIL
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: KIM IL-SOO
Owner Business Name: PROGRESSIVE MGMT OF NY CO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND                       
Buildings Total                       
Total Units : 5 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 03/24/2014
Power Issued: Response: F - FILED TO REMOVE OBJECTION 11/07/2013

Follow-Up: X - FILED APPL,NOW CLOSED 11/07/2013
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y153739
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/08/2010 11/22/2010 GYM W (35) (8)
INSPECTION COMMENTS: V
 
(2) 03/14/2014 03/24/2014 JSV A R (60) (1) Y
INSPECTION COMMENTS: ISSUE OBJECTIONS TO CONTRACTOR
 
(3) 04/09/2014 04/16/2014 PDI C R (20) (0) Y
INSPECTION COMMENTS: CERT

OBJECTION FOR APPLICATION #: Y153739
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
WALK IN COOLERS/FREEZERS (BR WIRING)
RSLV 11/08/2010 11/08/2010 03/14/2014
 
002 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
A)PANELS,LIGHTS,SWS,RECEPT,COMPRESSOR,2 SET 500 MCM 400A DISC SWFEEDS ,ETC
RSLV 11/08/2010 11/08/2010 03/14/2014
 
003 ( 24) ARMORED CABLES ARE NOT PROPERLY SECURED
SUPERMARKET THRU-OUT,1FL & BSMT
RSLV 11/08/2010 11/08/2010 03/14/2014
 
004 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
SUPERMARKET THRU-OUT,1FL & BSMT
RSLV 11/08/2010 11/08/2010 03/14/2014
 
005 ( 29) OUTLET BOXES ARE NOT COVERED
SUPERMARKET THRU-OUT,1FL & BSMT
RSLV 11/08/2010 11/08/2010 03/14/2014
 
006 ( 30) OUTLET BOXES ARE NOT SECURED
SUPERMARKET THRU-OUT 1FL & BSMT
RSLV 11/08/2010 11/08/2010 03/14/2014
 
007 ( 50) TEMPORARY OPEN WIRING IN CONTACT WITH PARTS OF THE BUILDING
SUPERMARKET THRU-OUT 1FL & BSMT
RSLV 11/08/2010 11/08/2010 03/14/2014
 
008 ( 49) TEMPORARY OPEN WIRING INSTALLED IS NOT PROPERLY SUPPORTED
SUPERMARKET THRU-OUT 1LF & BSMT
RSLV 11/08/2010 11/08/2010 03/14/2014
 
009 ( 30) OUTLET BOXES ARE NOT SECURED
1ST FLOOR FIXTURES
RSLV 03/14/2014 03/14/2014 04/09/2014