BIS Menu  |  Elevators  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y144037
Premises: 2922 GRAND CONCOURSE BRONX BIN: 2017622     Block: 3320   Lot: 60
   
Application Completed and Certified

Filed: 2922 GRANDCONCOURSE Census Tract:   407.02 Health Area:  0420
OUTSIDE BUILDING Admin Area:   Y - BRONX Inspection Area:   H
BRONX, NY 10458 Community Board:   207
Related Job Number:    210039126
DOB Cross Street(s):   EAST 199 STREET,    BEDFORD PARK BOULEVARD
Status:   C - JOB IS SIGNED OFF 10/19/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/16/2008 4:17 PM
Application Entered:   10/16/2008 Job Start Date:   10/20/2008
Last Change:   10/19/2013 Job End Date:   10/20/2009
Appointment Status:   
Last Inspection By:   IACOPETTA, JOSEPH       On     10/16/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 012074 Licensee Name: RAVI MANGROO
Firm: 003771 Firm Name: GUIDING LIGHT ELECTRIC IN
Firm Phone: 718-847-5700  Firm Address: 125-18 101ST AVENUE, 1FL S. RICHMOND.HILL,QUEENS NY 11419 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
W - SIDEWALK SHED WIRING & LIGHTING
Total Fee:  $40.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JACOB SELECHNIK
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001                   
Buildings Total                   
Total Units : 9 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:   TEMP BRIGE LIGHTING FOR SIDE WALK SHED

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y144037
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/16/2013 10/19/2013 JIC C (15) (0) Y
INSPECTION COMMENTS: C