Electrical Application Details for App #: Y135915
Premises: 471 EAST TREMONT AVENUE BRONX BIN: 2115978     Block: 3043   Lot: 1
   
Application Completed and Certified

Filed: 1920 WASHINGTON AV Census Tract:   377 Health Area:  1700
ALL FLOORS Admin Area:   Y - BRONX Inspection Area:   I
BRONX, NY 10457 Community Board:   206
Related Job Number:    201042166
DOB Cross Street(s):   EAST TREMONT AVENUE,    EAST 178 STREET
Status:   C - JOB IS SIGNED OFF 02/26/2008
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/16/2007 Job Start Date:   03/30/2007
Last Change:   02/26/2008 Job End Date:   03/30/2008
Appointment Status:   
Last Inspection By:   PETER CONTEY       On     02/08/2008      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 009904 Licensee Name: WILLIAM IZZO
Firm: 000701 Firm Name: IZZO ELECTRIC INC.
Firm Phone: 718-904-0164  Firm Address: 2522 EAST TREMONT AVENUE BRONX NY 10461 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $4,592.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: CHRIST TSETSEKAS
Owner Business Name: ARTEC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  3  
D. 601 Up to 1200 AMPS  1  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  73  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  6  
D. Over 250 MCM  9  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  73  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  6  
D. 3 Phase Over 225 AMPS  1  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 199  960  159  384  199     38           
Total Units : 1939 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 73 #4-Wire 1 #10-Wire 2
Existing Meters 0 + New Meters 76 - Removed Meters 0 = Total Meters 76

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/16/2007 Notice:  
Power Issued: 04/16/2007 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y135915
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/08/2008 02/20/2008 PC2 C E (105) (0) Y
INSPECTION COMMENTS: C