Electrical Application Details for App #: Y132316
Premises: 3097 HEATH AVENUE BRONX BIN: 2114270     Block: 3261   Lot: 52
   
Application Completed and Certified

Filed: 3103 HEATH AV Census Tract:   277 Health Area:  0310
ENTIRE Admin Area:   Y - BRONX Inspection Area:   H
BRONX, NY 10463 Community Board:   208
Related Job Number:    201033032
DOB Cross Street(s):   SUMMIT PLACE,    FORT INDEPENDENCE STREET
Status:   C - JOB IS SIGNED OFF 04/11/2007
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/17/2006 3:53 PM
Application Entered:   07/17/2006 Job Start Date:   07/19/2006
Last Change:   04/11/2007 Job End Date:   11/01/2006
Appointment Status:   
Last Inspection By:   PETER CONTEY       On     04/03/2007      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010641 Licensee Name: WILLIE THROWER, JR.
Firm: 002858 Firm Name: NOBLE ELECL CONTRG CO INC
Firm Phone: 718-299-9472  Firm Address: 1794 CLINTON AVENUE BRONX NY 10457 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $316.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   E - Four Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOSHUA WEISSMAN
Owner Business Name: JACKSON DEVELOPMENT
Authorized Representative:  JOSHUA WEISSMAN
Relationship To Owner:   PROJECT MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  5  BREAKER ENCLOSURE.
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  4  
B. Over #2 to 1/0  1  1/0 AWG
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  5  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 47  103  15  35  47                
Total Units : 247 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 5 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 5 - Removed Meters 0 = Total Meters 5

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 07/17/2006 Notice:  
Power Issued: 07/17/2006 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y132316
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/18/2006 12/20/2006 PC2 J E (60) (0) Y
INSPECTION COMMENTS: ALL WORK NOT COMPLETE, BASEMENT AND SERVICE WORK NOT COMPLETE. CHECK WATER METER BONDING JUMPER. CHECK GROUND ROD CONDUCTOR CONNECTION CHECK SIZE OF SWITCH AND RISER C.B. SIZE
 
(2) 04/03/2007 04/06/2007 PC2 C E (60) (0) Y
INSPECTION COMMENTS: CERT