Electrical Application Details for App #: Y131700
Premises: 5 MINERVA PLACE BRONX BIN: 2017596     Block: 3319   Lot: 64
  Printable (PDF) version of this Permit  

Filed: 5 MINERVA PL Census Tract:   407.01 Health Area:  0420
NONE Admin Area:   Y - BRONX Inspection Area:   H
BRONX, NY 10468 Community Board:   207
DOB Cross Street(s):   JEROME AVENUE,    CRESTON AVENUE
Status:   P - OBJECTN PENDING AT CONTRACTOR 12/03/2009
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   05/26/2006 Job Start Date:   06/09/2006
Last Change:   12/03/2009 Job End Date:   03/09/2007
Appointment Status:   
Last Inspection By:   PETER CONTEY       On     12/01/2009      
Field Disp:   H - NO PROGRESS ON JOB
Energize Recommendation:  
Objection Disposition:  X - NOT REMOVED

License #: 010275 Licensee Name: FRANK RAPPO
Firm: 001195 Firm Name: R & L SYSTEMS, INC.
Firm Phone: 718-397-5394  Firm Address: 37-20 56TH STREET WOODSIDE NY 11377 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
Total Fee:  $165.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   COMMERCIAL
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: WES CANCEL
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  1  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: C - CALL TO OFFICE 12/03/2009
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  DEVICE NUMBER:2P923

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y131700
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/11/2009 03/17/2009 PC2 V (60) (2) Y
INSPECTION COMMENTS: VIOLATIONS
 
(2) 12/01/2009 12/03/2009 PC2 H X (45) (0) Y
INSPECTION COMMENTS: C

OBJECTION FOR APPLICATION #: Y131700
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(A) NEC ARTICLE 250.112 ALL ELEVATOR CONDUITS INCLUDING FEEDER AND MOTOR BRANCH CIRUITS TO OPEN BOTTOM CONTROLLOR NOT BONDED
OPEN 03/11/2009 12/01/2009
 
002 (999) OTHER
(B) NEC ARTICLE 620.85 LIGHTING OUTLET WITH SWITCH AND GFC RECEPTALE NOT PROVIDED FOR ELEVATOR PIT AND IN ELEVATOR MOTOR ROOM
OPEN 03/11/2009 12/01/2009