BIS Menu  |  Elevators  |  Property Profile  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y130205
Premises: 3032 CRUGER AVENUE BRONX BIN: 2111221     Block: 4569   Lot: 16
   
Application Completed and Certified

Filed: 3032 CRUGER AV Census Tract:   338 Health Area:  0810
1ST, 2ND & 3RD FLOORS Admin Area:   Y - BRONX Inspection Area:   G
BRONX, NY 10467 Community Board:   212
Related Job Number:    200929326
DOB Cross Street(s):   ADEE AVENUE,    BURKE AVENUE
Status:   C - JOB IS SIGNED OFF 07/05/2006 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/25/2006 Job Start Date:   01/25/2006
Last Change:   07/05/2006 Job End Date:   04/25/2006
Appointment Status:   
Last Inspection By:   PETER CONTEY       On     06/22/2006      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 009939 Licensee Name: WARREN GANNES
Firm: 001705 Firm Name: GANECO ELECTRIC CORP.
Firm Phone: 718-882-1638  Firm Address: 1086 E. GUNHILL ROAD BRONX NY 10469 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $261.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Commercial/Residential (0  Stores, 53 Apartments)
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: JOHNSON AKINTAYO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  4  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  4  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 38  114  11  28  38                
Total Units : 229 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 4 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 01/25/2006 Notice:  
Power Issued: 01/25/2006 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y130205
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/22/2006 06/27/2006 PC2 C E (50) (0) Y
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.