BIS Menu  |  Elevators  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y129546
Premises: 671 MANIDA STREET BRONX BIN: 2006625     Block: 2765   Lot: 205
   
Application Completed and Certified

Filed: 671 MANIDA ST Census Tract:   99 Health Area:  4300
SIDEWALK BRIDGE Admin Area:   Y - BRONX Inspection Area:   J
BRONX, NY 10474 Community Board:   202
DOB Cross Street(s):   RANDALL AVENUE,    SPOFFORD AVENUE
Status:   C - JOB IS SIGNED OFF 04/27/2010
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/29/2005 Job Start Date:   10/06/2005
Last Change:   04/27/2010 Job End Date:   10/06/2005
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     04/20/2010      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011078 Licensee Name: EUGENE FITZGERALD
Firm: 002446 Firm Name: E. FITZGERALD ELEC CO INC
Firm Phone: 718-945-6828  Firm Address: 633 3RD AVE 17 FLOOR STE 1731 NEW YORK NY 10017 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
2 - TEMPORARY CONSTRUCTION
Total Fee:  $41.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   SIDEWALK BRIDGE
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: COLGATE SCAFFOLD
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 15                        
Total Units : 15 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 06/27/2008
Power Issued: Response: V - OBJ WAS REMOVED 05/06/2008

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y129546
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/19/2007 06/25/2007 GYM V (45) (9)
INSPECTION COMMENTS: N/A
 
(2) 06/22/2008 06/27/2008 GYM A R (30) (2)
INSPECTION COMMENTS: V
 
(3) 10/12/2008 10/16/2008 GYM J R (25) (0)
INSPECTION COMMENTS: SWB NOT REMOVED
 
(4) 04/20/2010 04/27/2010 GYM C (30) (0) Y
INSPECTION COMMENTS: SWB SHED TEMP INSTALL & REMOVED

OBJECTION FOR APPLICATION #: Y129546
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
OUTSIDE EMT CONDUCT SIDE WALK BRIDGE 358.12
RSLV 06/19/2007 06/19/2007 06/22/2008
 
002 ( 28) ELECTRICAL MATERIAL USED FOR LUMINAIRES HAS NOT BEEN APPROVED
OUTSIDE BRIDGE LIGHTS
RSLV 06/19/2007 06/19/2007 06/22/2008
 
003 ( 7) EMT IS NOT PROPERLY SUPPORTED (TYPE:EMT)
OUTSIDE EMT CONDUCT SIDE WALK BRIDGES
RSLV 06/19/2007 06/19/2007 06/22/2008
 
004 ( 16) DEFECTIVE LIGHTING FIXTURES ARE IN USE
OUTSIDE BRIDGE LIGHTS
RSLV 06/19/2007 06/19/2007 06/22/2008
 
005 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
OUTSIDE BIDGE LIGHTS
RSLV 06/19/2007 06/19/2007 06/22/2008
 
006 ( 19) DEFECTIVE WIRING IS IN USE
OUTSIDE BRIDGE LIGHTS
RSLV 06/19/2007 06/19/2007 06/22/2008
 
007 ( 45) FIXTURE NOT INSTALLED IN AN APPROVED MANNER
OUTSIDE BRIDGE LIGHTS
RSLV 06/19/2007 06/19/2007 06/22/2008
 
008 ( 29) OUTLET BOXES ARE NOT COVERED
OUTSIDE BRIDGE LIGHT
RSLV 06/19/2007 06/19/2007 06/22/2008
 
009 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
OUTSIDE FEEDS BRIDGE LIGHT ROMEX CABLES
RSLV 06/19/2007 06/19/2007 06/22/2008
 
010 (999) OTHER
OUTDOOR-SYSTEM IS NOT PROPERLY GROUNDED
RSLV 06/22/2008 06/22/2008 10/12/2008
 
011 ( 15) FLEXIBLE CORDS USED AS PERMANENT WIRING METHOD
OUTDOOR-SJ CORD FEED SWB SHED TEMP LTG
RSLV 06/22/2008 06/22/2008 10/12/2008