Electrical Application Details for App #: Y116949
Premises: 2870 GRAND CONCOURSE BRONX BIN: 2017172     Block: 3305   Lot: 20
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 2870 GRAND CONCOURSE Census Tract:   407.02 Health Area:  0420
NONE Admin Area:   Y - BRONX Inspection Area:   H
BRONX, NY 10458 Community Board:   207
DOB Cross Street(s):   MINERVA PLACE,    EAST 199 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/25/2003 Job Start Date:   08/11/2003
Last Change:   08/22/2025 Job End Date:   08/15/2003
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   EVON GRANDISON       On     08/20/2025      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  
Objection Disposition:  

License #: 009873 Licensee Name: JOE MIDDLETON
Firm: 001933 Firm Name: NORWAY ELECTRIC CORP.
Firm Phone: 718-992-5500  Firm Address: 1205 JEROME AVENUE BRONX NY 10452 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $145.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: ROWTIE HARRIRAM
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  4  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 4 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 4 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 08/25/2003 Notice: 1 - FIRST NOTICE 08/20/2025
Power Issued: 08/25/2003 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y116949
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/20/2025 08/20/2025 EVG V (30) (5)
INSPECTION COMMENTS: JOB FAILED. INSPECTION COMPLETE.

OBJECTION FOR APPLICATION #: Y116949
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (126) BASEMENT WATER MAIN GROUND NOT INSTALLED ON WATER MAIN
(BASEMENT) 250.64, GEC WIRE IS NOT CONNECTED TO THE WATER MAIN.
OPEN 08/20/2025 08/20/2025
 
002 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(BASEMENT)210.4 2 POLE BREAKERS ARE NEEDED FOR MULTI CIRCUITS SHARING ANEUTRAL.
OPEN 08/20/2025 08/20/2025
 
003 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(BASEMENT)CONTRACTOR NEEDS TO FILE A NEW PERMIT ADD 4 COMBO 100 SERVICESWITCHES TO THE APPLICATION.
OPEN 08/20/2025 08/20/2025
 
004 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(BASEMENT)320.30 ARMORED CABLE COMING OUT OF ELECTRICAL PANELS NEED TO BESUPPORTED.
OPEN 08/20/2025 08/20/2025
 
005 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(BASEMENT)200.6, THE NEUTRAL FOR MULTI THE CIRCUITS WIRES THAT IS ORANGE,NEEDS TO BE MADE INTO A WHITE WIRED NEUTRAL.
OPEN 08/20/2025 08/20/2025