NYC Department of Buildings
Electrical Application Details for App #: Y116731
Premises: 2041 ARTHUR AVENUE BRONX BIN: 2011995     Block: 3069   Lot: 1
   
Application Completed and Certified

Filed: 577 E 179 ST Census Tract:   375.03 Health Area:  1700
BSMT Admin Area:   Y - BRONX Inspection Area:   I
BRONX, NY 10457 Community Board:   206
Special Place Name:   PS 118,X
DOB Cross Street(s):   LAFONTAINE AVENUE,    ARTHUR AVENUE
Status:   C - JOB IS SIGNED OFF 12/01/2004
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/12/2003 Job Start Date:   08/11/2003
Last Change:   12/01/2004 Job End Date:   05/30/2004
Appointment Status:   
Last Inspection By:   PETER CONTEY       On     11/18/2004      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011748 Licensee Name: RICHARD SAJIUN
Firm: 001298 Firm Name: SAJIUN ELECTRIC INC.
Firm Phone: 212-675-2800  Firm Address: 118 EAST 28TH STREET STE 801 NEW YORK NY 10016 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $315.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   W - School
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: SILVIA HERSHER
Owner Business Name: SCA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 80    20  20  80     30           
Total Units : 230 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  BOILER ROOM RENOVATION

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y116731
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/18/2004 11/23/2004 PC2 C (90) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application