BIS Menu  |  Elevators  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y109197
Premises: 389 EAST 138 STREET BRONX BIN: 2000595     Block: 2301   Lot: 29
   
Application Completed and Certified

Filed: 389 E 138 ST Census Tract:   39 Health Area:  4500
2ND-5TH FL Admin Area:   Y - BRONX Inspection Area:   A
BRONX, NY 10454 Community Board:   201
DOB Cross Street(s):   ALEXANDER AVENUE,    WILLIS AVENUE
Status:   C - JOB IS SIGNED OFF 01/05/2004
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/02/2002 Job Start Date:   03/21/2002
Last Change:   01/05/2004 Job End Date:   08/31/2002
Appointment Status:   
Last Inspection By:   DORSAINVILLE, R       On     11/20/2003      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011352 Licensee Name: AARON KOLODNY
Firm: 002776 Firm Name: Z QUALITY ELECTRIC INC.
Firm Phone: 718-998-5597  Firm Address: 77-45 164TH STREET FLUSHING NY 11366 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $628.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:  
Owner / Occup: SHALOM JACOBS
Owner Business Name: 389 LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  9  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  9  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 64  160  16  28  64              
Total Units : 340 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 10 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/02/2002 Notice:  
Power Issued: 04/02/2002 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  WILLIS AVE NO WORK ON GROUND FLOOR 191440

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y109197
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/29/2002 11/12/2002 RID J (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 01/24/2003 01/30/2003 RID J E (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 11/20/2003 11/24/2003 RID C E (60) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Elevators  |  Electrical Inspection Work Order  |  Back