BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y091799
Premises: 98 EAST BURNSIDE AVENUE BRONX BIN: 2007948     Block: 2829   Lot: 45
   
Application Completed and Certified

Filed: 66 E BURNSIDE AV Census Tract:   241 Health Area:  1600
NONE Admin Area:   Y - BRONX Inspection Area:   F
BRONX, NY 10453 Community Board:   205
DOB Cross Street(s):   WALTON AVENUE,    MORRIS AVENUE
Status:   C - JOB IS SIGNED OFF 05/23/2002
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   12/31/1998 Job Start Date:   12/20/1998
Last Change:   04/25/2002 Job End Date:   02/25/1999
Appointment Status:   
Last Inspection By:   DORSAINVILLE, R       On     04/19/2002      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011328 Licensee Name: GORDON KONSKER
Firm: 002737 Firm Name: NEW AGE ELEC'L CONTRS INC
Firm Phone: 718-545-3333  Firm Address: 35-37 36TH STREET, STE#402 ***CANCELLATION*** LONG ISLAND CITY NY 11106 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $611.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   VARIOUS
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: MILLGROUK PROPERTIES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  4  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  6  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  2  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  2  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 7 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 12/31/1998 Notice: 1 - FIRST NOTICE 01/08/2002
Power Issued: 12/31/1998 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: NEW SERVICE & METERS EXISTING LOAD (SEE DIAGRAM)
Contractor's Comments:  66-96 EAST BURNSIDE AVE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y091799
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/02/2002 01/08/2002 RID V G (60) (5)
INSPECTION COMMENTS: 1CONDUCTOR NOT GROUNDED2NOT PROPER SIZE3COORDINATED-2ND FUSE.4COVERE D THIS IS NOT A FINAL INSPECTION
 
(2) 04/19/2002 04/25/2002 RID C R E (80) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order