BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y084564
Premises: 2 EAST MT EDEN AVENUE BRONX BIN: 2008139     Block: 2846   Lot: 32
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 6 E MOUNT EDEN AV Census Tract:   223 Health Area:  2320
GOUND FLOOR Admin Area:   Y - BRONX Inspection Area:   E
BRONX, NY 10452 Community Board:   204
DOB Cross Street(s):   JEROME AVENUE,    TOWNSEND AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/11/1997 Job Start Date:   08/08/1997
Last Change:   08/22/2025 Job End Date:   08/11/1997
Appointment Status:   
Last Inspection By:   LAWRENCE HAYES       On     05/05/1999      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  D - DON'T ISSUE POWER AUTH
Objection Disposition:  

License #: 009983 Licensee Name: C TRAPANI
Firm: 002234 Firm Name: CARMELO TRAPANI
Firm Phone: 718-256-2102  Firm Address: 40 BAY 17TH STREET BROOKLYN NY 11214 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $78.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   99 STORE
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: ELAINE GRCHOW
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 08/11/1997 Notice: 1 - FIRST NOTICE 05/11/1999
Power Issued: 08/11/1997 Response:  

Follow-Up:
Wires Comments: INSTALL NEW SERVICE
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y084564
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/05/1999 05/11/1999 LHY V D (45) (5)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order