Electrical Application Details for App #: Y084227
Premises: 1781 WEBSTER AVENUE BRONX BIN: 2009347     Block: 2890   Lot: 56
   
Application Completed and Certified

Filed: 1783 WEBSTER AV Census Tract:   231 Health Area:  1800
1ST FL Admin Area:   Y - BRONX Inspection Area:   D
BRONX, NY 10457 Community Board:   205
DOB Cross Street(s):   ITTNER PLACE,    EAST 175 STREET
Status:   C - JOB IS SIGNED OFF 12/21/1999
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   07/24/1997 Job Start Date:   07/24/1997
Last Change:   03/19/1999 Job End Date:   08/24/1997
Appointment Status:   
Last Inspection By:   LAWRENCE HAYES       On     03/12/1999      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009272 Licensee Name: F GAROFALO
Firm: 000458 Firm Name: EAST ELECTRIC OF NYC, INC
Firm Phone: 718-747-2930  Firm Address: 150-50 14TH ROAD WHITESTONE NY 11568 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $673.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   CAR WASH
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: M&M CAR WASH
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  1  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  3  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  1  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 33  30    68     163           
Total Units : 299 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 07/24/1997 Notice: C - CALL TO OFFICE 01/26/1999
Power Issued: 07/24/1997 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Y084227
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/27/1998 04/17/1998 LHY V E (20) (2)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 11/20/1998 11/27/1998 LHY H X (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 01/21/1999 01/26/1999 LHY J X (50) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 03/12/1999 03/19/1999 LHY C R E (40) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application